background image

WIP210 Panel 

www.videofied.com

Doc. - Ref.   230-WIP210

Last modification date : February 2015

Firmware version : XLP 05.21.03.XXX and later

I N S T A L L A T I O N   M A N U A L

W and WIP Panel

Summary of Contents for W Panel

Page 1: ...WIP210 Panel www videofied com Doc Ref 230 WIP210 Last modification date February 2015 Firmware version XLP 05 21 03 XXX and later I N S T A L L A T I O N M A N U A L W and WIP Panel ...

Page 2: ...W panel is compatible with every radio device manufactured by RSI VIDEO TECHNOLOGIES Technology The W alarm panel uses the S2View patented technology That interactive and wireless technology ensures signal integrity The bidirectional radio link maximizes the signal reliability AES encryption protects the communication between the panel and the devices Transmission security is optimal The jamming d...

Page 3: ...programming 7 ETHERNET parameters configuration 11 3 W panel features guide 15 3 1 Get to access level 4 15 3 2 How to arm disarm the system 15 3 3 Arming and siren mode configuration 16 3 4 Manage badges and access codes 17 3 5 Delete the keypad 19 3 6 Read the event log 20 3 7 Golden rules 20 4 Ethernet parameters 21 5 Transmitter events list 22 6 2G3G error codes 23 7 Security and certification...

Page 4: ...ion Status LEDs Mini USB connector forpowersupply Batteryconnector 1 2 Panel mounting Fix the back casing on the wall using the three mounting holes 4 mm diameter as shown Mounting the panel is not requiredforprogramming Bracketholes WIS100 Siren connector COMbutton INITbutton Lockingscrews I N S T A L L A T I O N M A N U A L ...

Page 5: ... Initialization Leave the panel open The green status LED de statut verte is on Press and hold the INIT button for 6 7 seconds until the status LED turns red for 1 second The red LED blinks several times then turns off That procedure resets the panel memory The panel is now reset a Videofied keypad has to be enrolled to configure the panel 1 3 Ethernet cable connection Once the panel is fixed on t...

Page 6: ... for the keypad to pair If the keypad does not pair up with the panel and shows XX it certainly means that it is stilled paired to another system The keypad needs to be reset Remove the batteries and press repeatedly on the keypad tamper switch for 30 seconds to 1 minute Then proceed to the above steps 1 6 Indicator lights Red LED on RedLEDblinking every3seconds Red LED off Green LED on AC power d...

Page 7: ...s important it measures the strength of communication between the device and the control panel The keypad will display a real time radio range value on a scale of 9 To receive the most accurate results you must run the radio range test for at least 30 seconds Result must be 8 out of 9 or better for reliable transmission OK orYES OK orYES Attendre OK orYES ESC NO for language selection OK orYES CON...

Page 8: ... to enter in a 4 8 digit account number provided by the Central Station CODE NAME OK orYES ACCESS 1 REGISTERED Wait ADJUSTING DATE AND TIME DATE YEAR 15 To set the year OK orYES DATE MONTH 15 01 To set the month OK orYES You may proceed in the same way for Day Hour and Minutes 15 01 19 10 47 ENTRY COMPLETE CONNECTED TO MONITOR STATION ACCOUNT NUMBER OK orYES ACCOUNT NUMBER 567001 OK orYES PERIODIC...

Page 9: ...Events list ESC NO SERVER ADRESSES OK orYES Wait ADRESSES SERVEUR IP1 ADDRESS 0 0 0 0 DOMAIN NAME 1 PORT 1 888 The IP1 address Domain Name 1 and or Port 1 are provided by the monitoring station Leave Port details at 888 unless otherwise instructed Press OK or YES to enter modify the parameter then OK or YES for validation WARNING You will use either an IP address or a Domain name but not both leav...

Page 10: ... the code exactly as indicated by your local SIM card operator Press OK or YES to enter modify the parameter then OK or YES for validation Note When entering your SIM card settings both APN codes username and password fields are case sensitive It makes a difference between UPPER and lower case letters To switch between UPPER and lower case use the M m key from CMA keypad or hold a digit key 0 9 fo...

Page 11: ...NO STATUS the Ethernet module is switched off Please verify that the Ethernet cable is connected and try again NETWORK CABLE MISSING the panel doesn t detect Ethernet Cable or Network By setting the DHCP as ENABLED a new IP address will be assigned dynamically to the panel every time it connects to the network Network parameters will not be asked If the router forces a static IP address for the pa...

Page 12: ...ES Available delays are 2 min 1 min 45 sec ENTRY DELAY 15 sec Available delays are 15 seconds 30 seconds 45 seconds 1 minute et 2 minutes For the selection OK orYES PRESS PROGRAM BUTTON OF DEVICE RECORDING DEVICES Each device has a unique programming button or a specific manipulation Please refer to the Installation Sheet for the device you would like to program DEVICE RECORDED OK orYES RADIO RANG...

Page 13: ...tion to be properly processed in case of alarm During the functional device test the device LED turns on when it detects an intrusion ENTERING A NEW DEVICE ESC NO Press OK or YES to enter another device or ESC NO to move on to the next step Each system can embrace a maximum of 25 devices programming keypad included RF TEST 9 9 BADGE ENTERED RECORDING A NEW BADGE END OF CONFIGURATION ESC NO ESC NO ...

Page 14: ...to comply with NF A2P and EN50131 standards OPERATION COMPLETED SYSTEM CHECK IN PROGRESS INSTALLATION SUCCESSFUL Before completing programming make sure that no device is tampered Each device must be closed and its LED indicator shall be turned off After initial programming has been completed make use of the menu overview document available on our technical support portal to see full programming o...

Page 15: ...tion of his panel OK orYES BADGE OR CODE 3 2 How to Arm Disarm the System When in standby mode the system can be armed with the remote keypad the remote keyfob and or the remote badge reader Full arming with personal code Full arming with badge Special Arming 1 Special Arming 2 With remote keypad Enter your user code and press OK orYES Present your badge on the keypad XMB model only Press enter yo...

Page 16: ... an alarm Areas 1 2 3 4 Each time you press the corresponding number the system will toggle the arming state for the respective area State A A A A Press OK YES after this configuration step The system will then display what siren mode will be in effect for this special profile Select the siren mode using the direction arrows then press OK YES A Armed D Disarmed P Perimeter bydefault allopeningcont...

Page 17: ...Modifications of the settings are not possible at this level User Level 3 can create Level 2 or Level 3 access codes or badges LVL 4 INSTALLER level where it is possible to modify the setup of the panel To access Level 4 the approval of a Level 3 oe Level 2 user is required Installer Level 4 can creat the first Level 3 access code only How to return to the LVL1 After 1 min of no use of the keypad ...

Page 18: ...an be registered into the panel with the engineer code A code has 4 to 6 digits 0 to 9 The table presents the reserved code possibilities that cannot be used Those codes are used for maintenance or as panic duress codes A total of 186 codes are forbidden Enter a new end user Badge Code Delete an end user Badge Code ENTER A BADGE CODE Press twice on the right arrow DELETING BADGES CODES Badges code...

Page 19: ...emove the batteries from the device ACCESS LEVEL 4 CONFIGURATION GENERAL PARAMETERS OK orYES to select the device and press OK orYES XX DELETE AREAS AND DEVICES DEVICES ADD A NEW DEVICE DEVICE CONFIGURATION A1 KEYPAD KEYPAD 1 OK orYES OK orYES OK orYES Devices list OK orYES OK orYES I N S T A L L A T I O N M A N U A L ...

Page 20: ...istake Never register the same device twice delete from the system first The panel can register of up to 25 devices of all types including the keypad and the keyfobs Follow the Motionviewer installation instructions Consider the infrared field of detection when installing the Montionviewer cameras in order to protect goods or an entry point instead of a zone 1 2 3 4 5 6 Do not fix the keypad at th...

Page 21: ...onnected constantly to the local Network In case of an alarm the alarm will be sent in few seconds to the monitoring station When the main power is cut the Ethernet module will switch off after a delay DELAY BEFORE OFF 30 by default in order to save battery life In case of an alarm the panel will at first connect to the local Network It adds few seconds to the total process of sending an alarm You...

Page 22: ...ION Use the arrows to access CONFIGURATION level4 CONFIGURATIONMONITOR STATION MONITORINGPARAMETERS EVENTTRANS MODIFICATION Then use the arrows to determine the event to modify Press OK orYES to edit These are the default transmitted events DEVICE intrusions ALERT Panic Buttons PANEL LOW BATT TAMPER DEVICE LOW BATT PERIODIC TEST DURESS CODE FIRE MEDICAL ASSIST ETHERNET CABLE AC POWER LOSS AC Power...

Page 23: ...list but it is representative of most cases Some events or codes are subject to change by SIM card operators However the 2G3G level test errors results in the majority of cases have the following causes SIM Card activation Delay Some operators require an additional delay up to 48 hours to activate automatic data transmission Please check with your operator prior to installation APN CODE USERNAME a...

Page 24: ...00 Fax 33 0 1 49 17 90 00 Sites Internet http www afnor org et http www marque nf com Email certification afnor org Certifications 868MHz WIP 210 220 230 and W 210 Compliant with the annex IV from the R TTE 1999 5 CE Directive NF A2P 2 boucliers suivant le référentiel NF324 H58 915MHz WIP 620 630 UL 1610 USA FCC Part 15C 22H 24E and 27 Canada IC RSS 210 Issue 8 RSS 132 RSS 133 and RSS 139 920MHz W...

Page 25: ...es and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmfulinterferencetoradiocommunications However thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encour...

Page 26: ...a Transmission security AES encryption algorithm Radio jam detection Yes Supervision Yes Antenna Integrated Tamper Detection Tamper Wall and cover tamper detection Transmission Communicator Communicator type 2G LAN Ethernet WIP210 2G W210 LAN Ethernet WIP220 WIP620 WIP720 3G LAN Ethernet WIP230 WIP630 WIP730 Security protocol Frontel IP Stack TCP IP Video transmission By Frontel protocol to centra...