Installation guidelines

For easier installation, programming and RF testing should be done 
before mounting to check for good communication between the 
control panel and all system devices

. Install the detector and other 

system devices in the following order:

>

 Programming/RF Testing - program detector and all other 

devices into the control panel and test RF communication from 
each intended device location to the control panel.

>

 Mounting - Mount detector at the tested location.

The ICT 702 universal door contact is designed 
for use with Videofied™ wireless security 
systems.
The contact includes the following features :
•  Completely wireless and powered by a 

Lithium battery

•    Dual tamper function provides detection for 

both wall and cover tamper

•  Transmits check-in/status signal every 8 

minutes

•    Wired input for wired detectors connection

Product presentation

Programming/RF Testing/Mounting

The  following  provides  summarized  steps  for  device 
programming, testing and mounting. For complete details, refer to 
the control panel installation manual.

Loosen the screw, open the box and 

insert the batteries.

Close the box and tighten the screw.

3

   Put control panel into configuration 

mode.

 Using a programmed keypad, proceed 

through menus until the display shows ADD 
A NEW DEVICE.

 Press YES/OK. The display shows 

PRESS PROGRAM BUTTON OF DEVICE.

Using a paperclip, press and release the 

contact INIT button. 

The contact LED flashes. Wait for the 
keypad to display DETECTOR (1-24) 
RECORDED.

  Press YES/OK. The display shows 

RADIO RANGE TEST?

Press YES/OK again. The detector LED 
starts flashing and keypad display shows 
TEST IN PROGRESS.

8

 

  Take  the  detector  to  its  intended 

mounting location and make sure that the 
LED flashes continuously, indicating good 
communication with the control panel.

9

 

Press YES/OK to end the radio range test then press ESC NO.

10

   The display shows AREA ASSIGNMENT AREA: 1. Press either 

arrow button repeatedly until desired AREA number appears, then 
press YES/OK.

11 

 The display shows PERIMETER DEVICE?

Press YES/OK or ESC NO, whichever is appropriate for this device 
(a device configured as PERIMETER will be armed for the “E” and 
perimeter special arming modes, only contacts protecting the 
external accesses should be configured for perimeter arming).

12

   The display shows NAME + LOCATION:

Enter appropriate device name/location (up to 16 characters), then 
press YES/OK. The display shows the device number and name for 
confirmation.

13 

 Press YES/OK. The display shows:

FUNCTIONAL DEVICE TEST? 

Caution: the panel records the current state of the detector 

and the current state of the wired input as being the normal 

state at the beginninfg of the functional device test :

•  The door contact must be closed at the beginning of the 

detection test to be configured as Normally Closed NC.

•  

If the wired input is open when recorded, it will be 

configured as Normally Open NO(and conversely).

That setting cannot be changed unless the contact is 

deleted from the panel programming and recorded again.

Press YES/OK again and verif y detector operation. For example, 
move the magnet next to the detector to make the LED go off, 
then  move  the  magnet  away  from  detector  to  make  LED  turn  on 
indicating detection.

14

   Press YES/OK to end detection verification.

15

   The display shows ENTERING A NEW DEVICE?

Repeat steps 1 - 14 for remaining detectors.

Screw

INIT button

LED

INSTALLATION SHEET

DOC. - REF.   219-ICT-AUS

MODIF. DATE : MAY 2017

VERSION : XX.XX.XX

1