Mounting procedure
>
Use proper tools and hardware.
>
To prevent false triggering the magnet must be aligned with
the upper part of the contact, following the markings. Use the
plastic adapters to align the magnet.
>
The magnet must always be mounted on the mobile part
(door).
Note: do not install the contact and its magnet on a ferromagnetic
support
>
The distance between the magnet and the contact must be
lower than 1 cm.
>
Install that device indoors with a controllled temperature.
Note: if only the wired input is used, installing the magnet is not
needed.
1
Remove the base from the contact.
2
Hold the base against the wall and
mark the mounting points.
3
Drill.
4
Mount the base on the wall.
5
If using the wired input,
connect 2 AWG22 wires from
the wired detector to the input
terminals.
6
Mount the detector on its base
and lock with the screw.
7
Insert the magnet in its case.
8
Use the plastic parts to place
the magnet next to the detector.
9
Hold the magnet base against the wall and mark the
mounting points.
10
Drill.
11
Fix the mounting with the appropriate screw
s.
Mounting
brackets
Connect to the
wired detector
terminals
2
INSTALLATION SHEET
INDOOR CONTACT TRANSMITTER
ICT 200/601/702/800