Victron energy SmartShunt IP65 Quick Installation Manual Download Page 2

5A - Second battery (option A)

• Connect the grey SmartShunt "Aux" wire (E) to the positive

battery terminal of the second battery.

• Make sure that the negative terminal of the second battery is

connected to the "LOAD MINUS" side of the SmartShunt.

5B - Battery midpoint (option B)

• Connect the grey SmartShunt "Aux" wire (E) to the battery

bank midpoint.

5C - Temperature sensor (option C)

• Use a (not included) "Temperature sensor for BMV". For more

info, scan below QR code or navigate to: 

https://ve3.nl/53

.

• For additional instructions consult the SmartShunt manual.

• Connect the red SmartShunt "VBatt +" wire (D) to the red wire

of the temperature sensor.

• Connect the grey SmartShunt "Aux" wire (E) to the black wire

of the temperature sensor.

• Connect the temperature sensor to the positive terminal of the

battery.

6 - GX device (optional)

• Connect the VE.Direct cable socket (C) to one of the

VE.Direct ports on the GX device via a VE.Direct cable.

• For an overview of all GX devices scan below QR code or

navigate to: 

https://ve3.nl/Venus-OS:start

.

7 - VictronConnect app

• Download the VictronConnect app.

• For more information about the VictronConnect app scan

below QR code or navigate to: 

https://ve3.nl/6z

.

• Connect with the VictronConnect app to the SmartShunt.

8 - VictronConnect settings

• Set the battery capacity.

• Set the functionality of the auxiliary input (if used).

• Set the charged voltage parameter as per below table.

System voltage

Charged voltage setting

12V

13.2V

24V

26.4V

36V

39.6V

48V

52.8V

Additional settings for lithium batteries:

• Set the charge efficiency at 99%.

• Set the Peukert exponent at 1.05.

Quick installation guide
SmartShunt IP65