Victron energy SmartShunt IP65 Quick Installation Manual Download Page 1

Battery safety warnings

• Working in the vicinity of a lead-acid battery is dangerous. Batteries can generate explosive gasses during operation. Never smoke

or allow a spark or flame in the vicinity of a battery. Provide sufficient ventilation around the battery.

• Wear eye and clothing protection.

• Avoid touching eyes while working near batteries. Wash your hands when done.

• If battery acid contacts skin or clothing, wash them immediately with soap and water. If acid enters an eye, immediately flood the

eye with running cold water for at least 15 minutes and get medical attention immediately.

• Be careful when using metal tools in the vicinity of batteries. Dropping a metal tool onto a battery might cause a short circuit and

possibly an explosion.

• Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a battery. A battery can produce

a short circuit current high enough to melt objects such as rings, causing severe burns.

1 - Introduction

• Familiarize yourself with the SmartShunt.

• The full manual is available online. Scan below QR code or

navigate to:

 https://ve3.nl/65

.

#

Connection

Terminal type

A

LOAD MINUS

M10 bolt

B

BATTERY MINUS

M10 bolt

C

VE.Direct (black wire)

VE.Direct plug

D

VBatt+ (red wire)

M10 ring terminal

E

Aux (grey wire)

M10 ring terminal

2 - Battery negative

• Connect the negative battery terminal to the SmartShunt

"BATTERY MINUS" terminal (B).

3 - DC system negative

• Connect the negative terminal of the DC electrical system to

the SmartShunt "LOAD MINUS" terminal (A).

4 - Power

• Connect the red SmartShunt "VBatt +" wire (D) to the positive

battery terminal.

Quick installation guide