Setting
Default
Range
Steps
Set alarm value
1.1V
0 - 95.0V
0.1V
Clear alarm value
1.0V
0 - 95.0V
0.1V
7.3.3. High voltage alarm
When enabled, the alarm will activate when the battery voltage rises above the set value for more than 10 seconds. The alarm
will deactivate when the battery voltage drops below the clear value.
Setting
Default
Range
Steps
Set alarm value
1.1V
0 - 95.0V
0.1V
Clear alarm value
1.0V
0 - 95.0V
0.1V
7.3.4. Low starter voltage alarm
This setting is only available if the Aux input has been set to “Starter battery”, see chapter
.
When enabled, the alarm will activate when the starter battery voltage falls below the set value for more than 10 seconds. The
alarm will deactivate when the starter battery voltage rises above the clear value.
Setting
Default
Range
Steps
Set alarm value
1.1V
0 - 95.0V
0.1V
Clear alarm value
1.0V
0 - 95.0V
0.1V