![Victron energy BlueSolar PWM Series Manual Download Page 7](http://html.mh-extra.com/html/victron-energy/bluesolar-pwm-series/bluesolar-pwm-series_manual_1014837007.webp)
5
EN
NL
FR
DE
ES
SV
IT
A
pp
en
dix
PV Voltage display
: PV voltage and the state of charge of
the battery.
Press MENU
to enter next display.
Charge current display: PV to battery current and the state
of charge of the battery.
Press MENU
to enter next display.
Load output settings.
The factory setting is 24h (load output always on)
Change load output
settings.
Press the MENU button
for several seconds until
the number flashes.
Load output setting.
See table below.
Press MENU
to enter
the next display
(Note: the Phoenix
VE.Direct inverters can be
controlled by connecting to
the left side connection of
the remote control to the
load output)
Trigger level
When the BlueSolar PWM Charge Controller
is set to L01-L23 the solar panel voltage will
be measured to decide whether it is night or
day to switch the load on or off.
The factory setting is 4V.
Press MENU
to enter
the next display
Trigger delay time
When the BlueSolar PWM Charge Controller
measures a solar panel voltage lower than
the trigger value it will delay for 10 seconds
and measure again to make sure night falls.
Factory setting: 10 seconds
H
The load can switched on and off by the
Load on/off switch
.
L
Load D2D
Load will switch on at sunset and switch off at sunrise.
L01-L23
The load output will switch on after sunset and switch off after 1-23
hours.
24H
The BlueSolar PWM Charge Controller will continuously supply
power to the load.