The load output settings also controls the streetlight algorithm. Both work together to protect the battery from being too deeply
drained. The streetlight settings are overridden should the battery voltage falls below the load disconnect voltage. When the
battery voltage increases to the load reconnect voltage, the streetlight function will resume.
5.2.3. Programmable relay settings
The programmable relay can be configured to a variety of relay modes. Each mode will cause the relay to switch under different
conditions. Some of these conditions are pre-determined and some are customizable. In addition to the "relay mode" a relay
minimum closed time can be set.
The programmable relay offers three connections:
• NO (Normally Open)
• C (Common)
• NC (Normally Closed)
Relay State
Connection
between
Switched
ON
C and NO
Switched
OFF
C and NC
Relay
C
NC
NO
Internal operation of the programmable relay
Relay mode
Description and notes
Relay always off
This option switches the relay OFF. It will disable the other relay options. Use this option if you do not
plan to use the relay function.
MPPT solar charger manual
Page 24
Configuration and settings