Victory VPP Installation And Operating Instructions Manual Download Page 10

User Manual for VPP & VPPD 

Victory

Rev. 10/2020

Victory

10

This is a cord-connected unit, and must be connected to its own 

dedicate

d power supply. Check the dataplate on the 

machine to confirm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.

Note: Do not connect to GFI / GFCI outlets. Connection to that type of outlet can result in product loss due to 
unsafe cabinet temperature when GFI device trips from moisture.

Power Cord

This 115 volt model is equipped with a cord and 5-15P plug.

If the power cord becomes damaged, it must be replaced 
with the identical cord.

Follow All National and Local Codes 

This Unit Must Be Grounded. Do not use extension cords 
and do not disable or by-pass ground prong on electrical 
plug.

Initial Start Up

Plug the power cord into the proper power supply.

The cabinet will soon begin to blow warm air out of the 
front grille area, and cool air will flow from the inside 
blower.

The cabinet temperature has been set at the factory and 
should not need adjustment, however if it was changed, 
the standard setting is 38º F.

Cautions

Care must be taken whenever moving or servicing the 
unit. The refrigerant is contained in a sealed system, but if 
released it is flammable.

Door Reversal Instructions

1.  Remove hinge cover

2.  Remove door from the unit to include the hinge 

mounting brackets

3.  Remove white hole covers from the side of the door 

opening you would like the hinges to be located (do 
not throw away)

4.  On the bottom of the door the same hole plugs are 

present and need to be removed

5.  Take the hole plugs and insert them into the screw 

holes where the hinges were originally located on the 
unit

6.  Install the hinge bracket upright on the unit.  The 

thick portion of the hinge bracket should be on the 
bottom as you mount them

7.  The door portion of the hinges need to be removed 

and rotated 180 degree and remounted

8.  Install the hole plugs that were removed from the 

bottom of the door into the holes where the handle 
was first mounted

9.  Install the handle on what is now the top of the door

10.  Slide door back into position and gently lower into the 

white pivot cam

11.  Replace hinge cover

ELECTRICAL

Summary of Contents for VPP

Page 1: ...ATING INSTRUCTIONS for all VPP and VPPD Models 3779 CHAMPION BLVD WINSTON SALEM NC 27105 Phone 888 845 9800 Fax 800 253 5168 Web victoryrefrigeration com 809 152A REV B 10 28 2020 SEE BACK COVER FOR W...

Page 2: ...on reserves the right to change specifications and product design without notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously...

Page 3: ...s There may be pinch points near the door hinges Maintenance Do NOT Clean a frozen evaporator with a sharp object Clean a dirty condenser with a sharp object Store gasoline kerosene or any other flamm...

Page 4: ...that have been altered in any way Alterations or part substitutions will void the warranty Limitations The machine is designed for use indoors in a controlled environment It must be kept dry not overh...

Page 5: ...5 1 2 4 5 1 3 VPPD72HC 3 72 x 37 x 53 5 1 3 4 5 1 3 VPPD72HC 4 72 x 37 x 53 5 4 4 5 1 3 VPPD72HC 6 72 x 37 x 53 5 6 4 5 1 3 VPPD93HC 2 93 x 36 5 x 55 5 2 2 7 8 1 2 120 4 23 VPPD93HC 4 93 x 36 5 x 55 5...

Page 6: ...nches at back None at sides Floor Load the floor on which the cooler is located must be even and level free from vibrations and strong enough to support the combined weights of the unit and maximum pr...

Page 7: ...be visible once screwed in 3 Tilt the cabinet in one direction approximately 8 and block it securely with pieces of 2x4 lumber or other suitable material 4 Thread the stem casters or legs into the 13...

Page 8: ...on bar facing up Be careful not to dislodge clips during installation 6 Place shelves so that the retaining tab on the clip captures the shelf as shown 7 Confirm that the shelf is resting on ALL 4 cli...

Page 9: ...ollow these instructions 1 Open the drawer to full extension 2 Push the white locking tabs forward on both sides of the drawer 3 Press down the back of the tabs 4 Slide the drawer out of the cabinet 5...

Page 10: ...actory and should not need adjustment however if it was changed the standard setting is 38 F Cautions Care must be taken whenever moving or servicing the unit The refrigerant is contained in a sealed...

Page 11: ...ase the melting or defrost button for a manual defrost Note Holding the defrost button in too long will shut the controller off The pans must be kept in place for proper temperature control The intern...

Page 12: ...he Compressor is not running The Condenser Fan is wired directly to the Compressor not through the controller EVAPORATOR FAN The Evaporator Fan runs continuously in refrigerators When the unit is plug...

Page 13: ...lease Increases Set Point Long press and release Increases display brightness DOWN Quick press and release Decreases Set Point Long press and release Decreases display brightness DEFROST ESC Quick pre...

Page 14: ...User Manual for VPP VPPD Victory Rev 10 2020 Victory 14 Control Panel Connections Changing the Set point...

Page 15: ...n If configured cut in alarm relay beep the buzzer Condenser alarm dor Door open for more than Always Blink dor If configured cut in alarm relay beep the buzzer Door open alarm uHi Line voltage is hig...

Page 16: ...ter 3 Dry with a soft cloth 4 Polish with a soft cloth wiping with the grain 5 Wipe weekly with stainless steel cleaner Weekly Interior Cleaning 1 Remove all food food related items and shelves Store...

Page 17: ...ut to release it 3 Pull grille carefully out and off the cabinet Condenser Coil 4 Examine condenser surface if dusty brush and vacuum the dust and lint from the surface of the coil Brush up and down t...

Page 18: ...unt of cleaner Heat tint or discoloration Penny Brite or Copper Brite Past NuSteel DuBois Temp or Tarnite Revere Stainless Steel Cleaner Allen Polish Steel Bright Tenacious Deposits Rusty Discoloratio...

Page 19: ...temp control No cooling compressor hums but does not start Low voltage to unit Compressor starting system failure Check voltage correct as needed Check start relay and start capacitor See next step No...

Page 20: ...ree from flame or spark It must also be in a well ventilated area with a nearby open window or door A sign noting service of a system containing propane must be attached to the unit during refrigerati...

Page 21: ...User Manual for VPP VPPD Victory Rev 10 2020 Victory 21 FOR THE SERVICE TECH WIRING DIAGRAM...

Page 22: ...door mechanisms or freight damage are not covered by this warranty For the purpose of this warranty the original purchaser shall be deemed to mean the individual or company for whom the product was o...

Page 23: ...EXPRESS IMPLIED OR STATUTORY INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE HEREBY DISCLAIMED AND ALL OTHER OBLIGATIONS OR LIABILITIES ON OUR PART A...

Page 24: ...______ Date Of Installation _________________ Cabinet Serial Number _____________________________________________ Location Of Product Business Name ____________________________________________________...

Reviews: