background image

CHARACTERISTICS

ONE SECTION 

TWO SECTION

Width, Overall

26 

1

/

2

52 

1

/

8

Depth, Overall (incl. handles)

29 

7

/

8

29 

7

/

8

Height, Overall (incl. adj. legs)

84

84

Total Capacity of Drawers (cubic Feet)

4

8

No. of Drawers

4

8

Drawer Pan - Width

14 

3

/

4

14 

3

/

4

Drawer Pan - Depth

19 

3

/

4

19 

3

/

4

Drawer Pan - Height

6

6

Cabinet Voltage

115/60/1

115/60/1

Feed Wires

2

2

Condensing Unit Voltage

115/60/1

115/60/1

Condensing Unit Size (HP)

1

/

4

1

/

3

Total Amperes

8.0

11.3

Victory participates in the KCL CADalog, the most current source of CAD symbols for foodservice designers worldwide. Symbols include
standard equipment in plan, side, front and 3-D views, layered for FEDA/FCSI recommended guidelines.

Continuous product development may necessitate specification changes and design without notice. 

Victory Refrigeration, Inc.

Shallow Depth Fish File Refrigerators

Crated dim. & wts.

Ht. Width Depth Cu.Ft. Lbs

One Section

82 36

1

/

2

44

3

/

4

77.5

565

Two Section

87

63

5

/

8

44

3

/

4

135.1 845

FOR REMOTE MODELS

– Substitute an “R” for the “S” in suffix. For

example: Model RS-1N-S7-FF (self-contained) would be RS-1N-R7-FF
remote cabinet. Air circulating fans, expansion valve and plasticized
coil are provided. Condensing units not supplied. The following units
are recommended with 

1

/

2

” O.D. Suction line, 

1

/

4

” O.D. Liquid line.

Dimensional tolerance ± 

1

/

4

”   Metric dimensions (MM)

REMOTE REFRIGERATION

Cond. Unit

BTUH

Cabinet

Amps

One Section

1

/

4

H.P.

2030

115/60/1

2.5

Two Section

1

/

3

H.P.

2540

115/60/1

3.4

Copyright June 2009

Printed in U.S.A. 063009

29.88

(758)

22.50

(571)

19.75

(502)

  9.62

  (245)

TYP OPN'G

13.12

(333)

26.38

(670)

28.38

(720)

  6.00

  (152)

DRAWER PAN

14.12

(358)

  21.12

  (537)

TYP OPN'G

13.25

(336)

6.00

(152)

26.50

(660)

84.00

(2133)

TOP VIEW

TOP VIEW

FRONT VIEW

FRONT VIEW

SIDE VIEW

CORD & PLUG

1.00" (25) NPT WASTE DRAIN 
CONNECTION TO FLOOR DRAIN

INTERIOR COIL

48.12

(1222)

29.88

(758)

84.00

(2133)

6.00

(152)

  21.12

  (537)

TYP OPN'G

52.13

(1324)

26.06

(662)

CORD & PLUG

1.00" (25) NPT WASTE DRAIN 
CONNECTION TO FLOOR DRAIN

INTERIOR COIL

NOTE: 

If cabinet is located

directly against wall an all
around clearance of 2” is
required, and a minimum
clearance of 10” under
ceiling.

We reserve the right to
change specifications and
product design without
notice. Such revisions do
not entitle the buyer to
corresponding changes,
improvements, additions or
replacements for previously
purchased equipment.