User Manual for RIS Refrigerators
Victory
Rev. 10/20
Victory
20
CONDENSER CLEANING
Keeping the condenser coil clean is critical to efficient
operation.
1. Unplug unit from power supply.
Rotating fan blade can cause
personal injury.
Unplug unit from power supply
before beginning to clean
condenser
CAUTION
2. Pull out on the bottom of the top panel to disengage
the locking clips
3. Raise the hinged panel
4. Remove the panel stand from its clip and secure into
the notch in the front right corner of the raised panel
5. Examine condenser surface, if dusty, brush and
vacuum the dust and lint from the surface of the
coil. Brush up and down to avoid damaging the fins.
Use care to not disturb the wires connected to the
controller.
Note: If the coil is greasy, the coil will need to be
cleaned with coil cleaner and that should be left to an
experienced technician.
6. To close, replace stand in its rest and lower panel
to the close position. Push firmly on the bottom to
engage locking clips
Note: Air filters are not recommended as they restrict
the flow of cooling air.
Condenser Surface