background image

Victory participates in the KCL CADalog, the most current source of CAD symbols for foodservice designers worldwide. Symbols include
standard equipment in plan, side, front and 3-D views, layered for FEDA/FCSI recommended guidelines.

Continuous product development may necessitate specification changes and design without notice. 

Victory  Refrigeration,  Inc.

Extra-H

High  Roll-IIn  Warming  Cabinets

Crated dim. & wts.

Ht. Width Depth Cu.Ft. Lbs

One Section

87 41

3

/

4

44

3

/

4

94.1 665

Two Section

87 74

5

/

8

43 168.1 970

Approximate Roll-Thru weights, add 15%

Dimensional tolerance ± 

1

/

4

”   Metric dimensions (MM)

Copyright January 2004

Printed in U.S.A. 010428

PART OF 

AGA

FOODSERVICE GROUP

39.38

(1000)

16.38

(416)

18.25

(463)

35.88

(911)

31.25

(793)

36.50

(927)

89.50

(2273)

27.75

(705)

72.25

(1835)

.88

(22)

ELEC.

CONN.

HUMIDITY 
VENT

ELEC.
CONN.

32.38

(822)

14.12

(358)

34.38

(873)

35.50 (902)

TO RAMP

89.50

(2273)

68.88

(1749)

.88

(22)

27.75

(705)

72.25

(1835)

27.75

(705)

39.38

(1000)

18.25

(463)

18.25

(463)

16.38

(416)

35.88

(911)

63.62

(1616)

ELEC.
CONN.

HUMIDITY

ELEC.
CONN.

VENT

ROLL-THRU MODELS

ROLL-IN MODELS

FRONT VIEW

FRONT VIEW

SIDE VIEW

NOTE: 

If cabinet is located directly against

wall and/or under low ceiling, a minimum

clearance of 2” is required.

If cabinet is located under low ceiling, a

minim clearance of 6” is required for

serviceability.

We reserve the right to change

specifications and product design

without notice. Such revisions do not

entitle the buyer to corresponding

changes, improvements, additions or

replacements for previously purchased

equipment.

CHARACTERISTICS

ONE SECTION

TWO SECTION

Roll-In

Roll-Thru

Roll-In

Roll-Thru

Width, Overall

36 

1

/

2

36 

1

/

2

68 

7

/

8

68 

7

/

8

Depth, Overall (incl. handles)

35 

7

/

8

39 

3

/

8

35 

7

/

8

39 

3

/

8

Height, Overall (incl. adj. legs) 

89 

1

/

2

89 

1

/

2

89 

1

/

2

89 

1

/

2

Depth, Doors Open 90º

65 

1

/

4

65 

1

/

4

65 

1

/

4

65 

1

/

4

Depth, Case Over Ramps

35 

1

/

2

35 

1

/

2

35 

1

/

2

35 

1

/

2

Clear Door Width

27 

3

/

4

27 

3

/

4

27 

3

/

4

27 

3

/

4

Clear Full Door Height

72 

1

/

2

72 

1

/

2

72 

1

/

2

72 

1

/

2

Capacity Net (cubic feet)

36.3

36.3

72.6

72.6

No. of Full Doors

1

2

2

4

Cabinet Voltage

208-240/60/1 208-240/60/1 208-240/60/1 208-240/60/1

Max. Fuse Size T.D.

15 Amps

15 Amps

20 Amps

20 Amps

Feed Wires

3

3

3

3

Heater Watts per Section (@240V)

1500

1500

1500

1500

Total Wattage (Heaters & Fan @240V)

1500

1500

3000

3000

Total Amperes

6.3

6.3

12.5

12.5

Reviews: