background image

Quartz Infrared Zone Heaters

 

 

The following information should be considered when installing Quartz Infrared 
Heaters. 

 
Installation should always be carried out by a qualified electrician or a competent person 
in accordance with current electrical regulations, protected by a suitably rated isolator 
and fuse. If using MCB’s type3 or typeC must be used. 
 

 

The heaters should always be installed using the mounting brackets provided to 
ensure adequate clearance from the wall. 

 

A minimum air gap of 450mm should always be allowed between the top of the 
heater and the ceiling or roof. 

 

A safety distance of 1mtr should always be left in front of a 1.5KW heater. Heaters 
of 3KW and 4.5KW should have a safety distance of at least 1.5mts and the 6KW 
heater leave 2mts. 

 

You also should ensure no flammable material could come into contact with the 
heater. 

 

Heaters should not be installed in areas where hazardous vapours may be present 
as defined in BS5345 

 

It is recommended the heaters be operated with a guard in front of the lamp and 
should always be fitted to units mounted below 2.2mtrs. 

 

The heater should only be installed in an indoor or weather protected environment. 

 
The essential element of the heater is a halogen filled quartz linear lamp with a tungsten 
element. This operates at about 2200

C and has a filter to stop most of the white light 

and emit short wave infrared radiant heat. The lamp operates at full infrared output 
almost instantly and emits radiant energy at 1.2microns. 
 

Quartz heaters are recommended by The Electricity council and Building Services 
Research Association for General space heating, Zone heating and localised spot 
heating. 
 

This product conforms to EU Directive 2002/96/EC. 
This appliance bears the symbol of the crossed waste bin. This 
indicates that, at the end of its useful life, it must not be disposed of 
as domestic waste, but must be taken to a collection center for waste 
electrical and electronic equipment. It is the user's responsibility to 
dispose of this appliance through the appropriate channels at the 
end of its useful life. Failure to do so may incur the penalties 
established by laws governing waste disposal. 

 
 
 

HeatLight  Technology

 

 

Quartz  Infrared 

 

HLQ  Series  Heating 

 

 
 
 
 
 
 
 

VICTORY (HeatLight Technology) 

Unit 36, Orbital 25 Business Park 

Dwight Road 

Watford 

WD18 9DA   U.K. 

 

Tel:  +44 (0) 1923 804080 
Fax: +44 (0) 1923 804081 

www.heatlight.com 

[email protected] 

 
 
 
 
 

INSTRUCTIONS SHOULD BE CAREFULLY READ BEFORE 

INSTALLATION AND RETAINED BY THE USER. 

 

Reviews: