User Manual for CBR Refrigerator
Victory
Rev. 10/20
Victory
16
CONDENSER CLEANING
Rotating fan blade can cause
personal injury.
Unplug unit from power supply
before beginning to clean
condenser
CAUTION
Keeping the condenser coil clean is critical to efficient
operation.
The condenser coil is located behind the front or rear
grille of the cabinet. It should be inspected once a month
and cleaned as required. Vacuum clean all surfaces of the
condenser. Make sure no fins are bent or damaged in the
process. If there are bent fins, carefully straighten them
so that air can flow through the coils. Failure to keep
the condenser coil clean will lead to poor performance,
excessive power consumption and compressor failure
and may result in loss of property. Failure to keep the
condenser coil clean may void the limited warranty.
1. Unplug unit from power supply.
2. Remove the bottom screw from the front grille panel.
3. Lift upwards on the front panel to remove
4. Examine condenser surface, if dusty, brush and
vacuum the dust and lint from the surface of the
coil. Brush up and down to avoid damaging the fins.
Use care to not disturb the wires connected to the
controller.
Note: If the coil is greasy, the coil will need to be
cleaned with coil cleaner and that should be left to an
experienced technician.
5. After the condenser is clean, return the grille panel to
the unit.
6. To reinstall the front panel line up the keeper screws
behind the panel and firmly pull downwards
7. Reinstall the screw on the bottom of the front grille
panel.
8. Reconnect electrical power and check operation.
Note: Air filters are not recommended as they restrict
the flow of cooling air.
Bottom Screw