02.2020
INSTRUCTION MANUAL
for installation and operation of pellet stove
VITTORIA В*
21
Activated timer
Red color:the timer is activated and waiting for the set time
to stop the stove.
Activated timer
Green color:the timer is activated and waiting for the set
time to start the stove.
Clogged
Chimney
The alarm is triggered when the fire door is opened or the
chimney is clogged.
t2 Problem
Problem with the thermo couple for the outlet gases.
IRS Sensor
Malfunction at input Ain2.
Boiler Sensor
Malfunction with sensors for temperature of “boiler up”
and “boiler down”.
Battery Low
Low battery of the control unit.
Pressing any of the alert icons leads to redirecting to the Alert Menu, where the hours and types of the alert are listed
descending.
In the Alert Menu there can be up to 6 alert events in the process of operation of the system.
14.CHECKLIST.
Location and installation:
-
Ventilation of the room;
-
Only the flue outlet of the pellet stove is connected to the chimney;
-
Connecting flues pipes have a horizontal section with a length of maximum 2 m, minimum slope of 3%, not more
than two curves at 90° and a vertical section with a length of less than 1.5 m;
-
Connecting flues pipes are made of suitable material. It is recommended stainless steel;
-
Heated capacity is properly calculated in accordance with the efficiency of radiators and required power in kW;
-
Heating system has to be implemented in accordance with current regulations and laws.
Operation:
-
Well dried and of good quality wood pellets. Diameter of Ø 6 mm and maximum moisture content of 8%;
-
Chimney, connecting flue pipes and combustion chamber are clean;
-
The cleaning elements are moved every day;
-
The pipes of the integral boiler and all parts of the combustion chamber are clean;
-
Flue outlet is cleaned;
-
The system is vented;
15.Frequently Asked Questions.
The following answers are tentative. For more details, use the instruction manual.
What is needed to prepare and do before installing the pellet stove?
Chimney with a diameter of at least 100 mm.
Opening for fresh air with a cross section not less than 80 cm
2
.
¾" connections for input and output to the heating system.
½" drainage connections for hydraulic safety valve.
Power supply 230V (+/- 10%), 50Hz.
Can the pellet stove be operated without water?
NO. Using pellet stove without water leads to damage.
Can the inlet and outlet of the integral boiler to be connected directly to the radiators?
NO. The connecting must be carried out in accordance with the indicated "Hydraulic Wiring Diagram".
Does the pellet stove provides hot water for sanitary purposes?
Provides opportunity by mounting a serpentine in the boiler for hot sanitary water.
Can the flue gases be removed directly out through the wall?
NO. Removal must be in accordance with existing standards. For proper operation of the pellet stove the chimney
(metal or masonry) has to be completed by one of the proposed variants at Fig. 5. It must be equipped with protection from
wind.
Does it need to make a hole for fresh air in the room?