background image

02.2020

 

 

 

INSTRUCTION MANUAL 

for installation and operation of pellet stove

VITTORIA В*

 

 

 

21

 

 

 

 

Activated timer 

Red color:the timer is activated and waiting for the set time 
to stop the stove. 

 

 

Activated timer 

Green  color:the  timer  is  activated  and  waiting  for  the  set 
time to start the stove. 

 

Clogged 
Chimney

 

 

The alarm is triggered when the fire door is opened or the 
chimney is clogged. 

 

t2 Problem

 

 

Problem with the thermo couple for the outlet gases.  

 

IRS Sensor

 

 

Malfunction at input Ain2. 

 

Boiler Sensor

 

 

Malfunction  with  sensors  for  temperature  of  “boiler  up” 
and “boiler down”. 

 

Battery Low

 

 

Low battery of the control unit. 

 

   Pressing any of the alert icons leads to redirecting to the Alert Menu, where the hours and types of the alert are listed 
descending. 

In the Alert Menu there can be up to 6 alert events in the process of operation of the system. 

 

14.CHECKLIST. 

Location and installation: 

-

 

Ventilation of the room; 

-

 

Only the flue outlet of the pellet stove is connected to the chimney; 

-

 

Connecting flues pipes have a horizontal section with a length of maximum 2 m, minimum slope of 3%, not more 
than two curves at 90° and a vertical section with a length of less than 1.5 m; 

-

 

Connecting flues pipes are made of suitable material. It is recommended stainless steel; 

-

 

Heated capacity is properly calculated in accordance with the efficiency of radiators and required power in kW; 

-

 

Heating system has to be implemented in accordance with current regulations and laws. 

Operation: 

-

 

Well dried and of good quality wood pellets. Diameter of Ø 6 mm and maximum moisture content of 8%; 

-

 

Chimney, connecting flue pipes and combustion chamber are clean; 

-

 

The cleaning elements are moved every day; 

-

 

The pipes of the integral boiler and all parts of the combustion chamber are clean; 

-

 

Flue outlet is cleaned; 

-

 

The system is vented; 

 

15.Frequently Asked Questions. 

The following answers are tentative. For more details, use the instruction manual. 

What is needed to prepare and do before installing the pellet stove? 

Chimney with a diameter of at least 100 mm. 

Opening for fresh air with a cross section not less than 80 cm

2

¾" connections for input and output to the heating system. 

½" drainage connections for hydraulic safety valve. 

Power supply 230V (+/- 10%), 50Hz. 

Can the pellet stove be operated without water? 

NO. Using pellet stove without water leads to damage. 

Can the inlet and outlet of the integral boiler to be connected directly to the radiators? 

NO. The connecting must be carried out in accordance with the indicated "Hydraulic Wiring Diagram". 

Does the pellet stove provides hot water for sanitary purposes? 

Provides opportunity by mounting a serpentine in the boiler for hot sanitary water. 

Can the flue gases be removed directly out through the wall? 

NO.  Removal  must  be  in  accordance  with  existing  standards.  For  proper  operation  of  the  pellet  stove  the  chimney 

(metal or masonry)  has to be completed by one of the proposed variants at Fig. 5. It  must  be equipped with protection from 
wind. 

Does it need to make a hole for fresh air in the room? 

Summary of Contents for Vittoria B

Page 1: ...INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA...

Page 2: ...ONTROL UNIT 12 10 2 3 MAIN MENU 13 10 2 4 INSTALLER SETTINGS 15 10 2 5 SERVICE TECHNICIAN SETTINGS 16 11 INSTRUCTION MANUAL 17 11 1 WOOD PELLETS LOADING 17 11 2 WOOD PELLET REFUELING 17 11 3 STARTING...

Page 3: ...failure of any of its components Safety components are activated without outside interference Necessary for the proper operating of the pellet stove is its proper installation in accordance with the...

Page 4: ...l data and dimensions Fig 1 Air inlet 50 mm Flue socket 80 mm Main switch with integrated socket for power cable D Circulation pump E Cold water inlet G F Hot water outlet G G Outlet pipe G for safety...

Page 5: ...xpansion vessel capacity 8 l Cold and hot water inlets dimensions 3 4 Pellet fuel hopper capacity 26 kg Flue socket diameter 80 mm Heating volume 470 m 3 Net weight 268 kg The dimensions of the heated...

Page 6: ...of the water into the integral boiler and sends information to the control system Hydraulic safety valve Upon reaching a pressure of 3 0 bar the system is activated to emit liquid After discontinuatio...

Page 7: ...onnect the heating system to the sewer 7 Operating mode Pellet stove works with wood pellets These are cylindrical granules made of pressed wood whose combustion is controlled by an electronic control...

Page 8: ...cause blockage of the auger and to stop the operation of the pellet stove IF PELLET STOVE BLOCKED THE REASON WILL APPEAR ON THE DISPLAY AND IT WILL BE SAVED Using low quality wood pellets or non manu...

Page 9: ...lue gases to safe for human health altitude over the area of habitation It is recommended that the pellet stove can be installed as close as possible to the chimney in order to reduce the number of co...

Page 10: ...eat consumers 10 Three way mixing valve thermostatic 11 Stopcock 12 Filter 13 Manometer 6 bar 14 Built in circulation pump The installation hydraulic diagram is indicative and does not replace the doc...

Page 11: ...ig 3 This operation must be repeated in the first days of use and when the system is recharged even partially The presence of air in the heating system can aggravate proper operation of the pellet sto...

Page 12: ...and then it would disappear in this case one can sure that the value has been saved correctly Just in case during the time of saving access to the Back Icon is denied to prevent involuntary interrupt...

Page 13: ...Fan Should one chose Turns then the fan would transfer to Set the Power Mode Should one chose Flow then the Fan would transfer to Flow Supervise Mode Mode of operation Here Heating Mode is firmly fix...

Page 14: ...imer ON shall not be active The delayed start is an autonomous one time timer which one can set a particular date and hour on to start the fireplace Its effect is a one time individual one The third o...

Page 15: ...can be locked in two ways The first one is to hold for more than 3 seconds the Title Page Settings Icon The second one is automatically while transitioning to Standby Mode of the Display in 10 minute...

Page 16: ...an to operate at 100 in Clean Mode This mode gets active if the contol unit transfers to switch off and extinction of the fireplace 600sec Period Here one cans et the time from 100 to 1000 seconds in...

Page 17: ...Start Mode In this mode what happens is the so called initial clean which lasts 60 seconds by default The smoke fan is set on maximum speed to clean the ashtray If we would like we can change the tim...

Page 18: ...are on Modulation 5 on pressing the selection field it will redirect to Modulation Change Menu It is important to note that this change is permanent It is saved and on restarting the control unit and...

Page 19: ...pump Check sensors Clean check and remove all debris from the ignition system Clean and check the electronic control system Check all electrical cables Clean the pellet fuel hopper and check auger to...

Page 20: ...given icon Exhaust gases High temperature of the combustion chamber above380 0 To remove the alarm the temperature has to drop below this value The stove continues to work Exhaust gases High temperat...

Page 21: ...in accordance with current regulations and laws Operation Well dried and of good quality wood pellets Diameter of 6 mm and maximum moisture content of 8 Chimney connecting flue pipes and combustion ch...

Page 22: ...ellet stove is designed to work with wood pellets with a diameter of 6 mm The use of another type of fuel leads to damage SPARE PARTS CATALOGUE Denomination Denomination 1 Gear motor for auger 17 Fire...

Page 23: ...02 2020 INSTRUCTION MANUAL for installation and operation of pellet stoveVITTORIA 23...

Page 24: ...Victoria 05 Ltd 24...

Page 25: ...internal contact with fire or hot surfaces Pellet stove is equipped with safety components that guarantee lock it automatically in case of failure of any of its components Safety components are activ...

Page 26: ...ease contact you dealer Any warranty repair of the pellet stove is recorded in the diary of warranty Warranty of the pellet stove is NOT VALID in the following cases Quickly worn out components glass...

Page 27: ...02 2020 INSTRUCTION MANUAL for installation and operation of pellet stoveVITTORIA 27 DIARY for repairs under warranty Company Receipt date Type of repair Delivery date Carried out...

Page 28: ...Victoria 05 Ltd 1BIvan Momchilov Str 5100 Gorna Oryahovitsa Republic of Bulgaria phone 359 618 60282 E mail info v05 bg http www v05 bg...

Reviews: