background image

Victoria-05 Ltd.

 

 

 

18 

 

Switching among these is based on the temperature, preset as water heater temperature. 
- if the water heater temperature is set to 50°С. 
- in the Modulation 5 Menu / the Thermal Difference one should set is 4°С 
- in the Modulation 4 Menu / the Thermal Difference one should set is 3°С 
- in the Modulation 3 Menu / the Thermal Difference one should set is 2°С 
- in the Modulation 2 Menu / the Thermal Difference one should set is 1°С 
- in the Modulation 1 Menu / the Thermal Difference one should set is 0°С 
Under the parameters set as above, the process will go like this: 
On reaching 46°С, which is 4°С below the preset, Modulation 4 will launch. 
On reaching 47°С, which is 3°С below the preset, Modulation 3 will launch. 
On reaching 48°С, which is 2°С below the preset, Modulation 2 will launch. 
On reaching 49°С, which is 1°С below the preset, Modulation 1 will launch. 
On reaching the preset temperature, the device will transfer to Stop Mode. 
In the Stop Mode, Clean on Extinct Fire will launch.  

On passing the time for Clean on Stop, the device would transfer to Green Eco Mode. In 
the Eco Mode, there are two important events to emerge. 
The first one is for the Time Clock, which has been preset to 600 seconds, to run out, and 
only after that the water heater temperature is checked to have decreased down below 
the preset one; these two events having taken place, only then can the device transit 
again to Start, Fuel, Ignition, etc. Modes... 

 

 
 

The Modulations can be changed through pressing the mode display field on which modulation the device is to operate 
under! 
            
Meaning, if we are on Modulation 5 on pressing the selection field, it will redirect to Modulation Change Menu. 

It is important to note that this change is permanent. It is saved and on restarting the control unit and reaching the 
modulations, if Modulation 2 is preset, then the device would transfer to it directly! 

12.Maintenance. 

Disconnect the power supply of the pellet stove before performing any activity 

Vacuum the combustion chamber before each ignition. If the combustion is interrupted, do not light a pellet stove again 

until you have emptied and cleaned the combustion chamber. 

The wood pellets, which are subtracted from the combustion chamber, should not be put back in the pellet 
fuel hopper! 

To operate properly, the pellet stove must be regularly serviced. If you do not perform regular maintenance (thorough cleaning 
at least once per season), this may lead to  improper operation of the pellet  stove. Any problems arising from lack of cleaning 
lead to void the warranty. 

12.1. Daily cleaning. 

For  better  heat  transfer  and  reduce  fuel  consumption,  its  needed  daily  cleaning  of  soot  in  flue  channels.  While  pellet  stove 
works, open the top door and by energetic movements up / down get clean the elements through the channels with the handle 
(Fig.6). Suffice cleaning is required once a day. In the manipulation, wear protective gloves. 

        

 

Fig.6.                                         Fig.7.                                        Fig.8.                                     Fig.9.

 

Activities to be carried out during the cleaning, only when the pellet stove is cold. Clean the pellet stove with a vacuum cleaner 
only when it is completely cold. The procedure takes a few minutes. 

-

 

Open the lower door and throw away the ashes from the ashtray (Fig.7); 

-

 

Open the middle door and remove the combustion chamber or use the spatula to scrape off any scales that clog the 
holes (Fig.8); 

Summary of Contents for Vittoria B

Page 1: ...INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA...

Page 2: ...ONTROL UNIT 12 10 2 3 MAIN MENU 13 10 2 4 INSTALLER SETTINGS 15 10 2 5 SERVICE TECHNICIAN SETTINGS 16 11 INSTRUCTION MANUAL 17 11 1 WOOD PELLETS LOADING 17 11 2 WOOD PELLET REFUELING 17 11 3 STARTING...

Page 3: ...failure of any of its components Safety components are activated without outside interference Necessary for the proper operating of the pellet stove is its proper installation in accordance with the...

Page 4: ...l data and dimensions Fig 1 Air inlet 50 mm Flue socket 80 mm Main switch with integrated socket for power cable D Circulation pump E Cold water inlet G F Hot water outlet G G Outlet pipe G for safety...

Page 5: ...xpansion vessel capacity 8 l Cold and hot water inlets dimensions 3 4 Pellet fuel hopper capacity 26 kg Flue socket diameter 80 mm Heating volume 470 m 3 Net weight 268 kg The dimensions of the heated...

Page 6: ...of the water into the integral boiler and sends information to the control system Hydraulic safety valve Upon reaching a pressure of 3 0 bar the system is activated to emit liquid After discontinuatio...

Page 7: ...onnect the heating system to the sewer 7 Operating mode Pellet stove works with wood pellets These are cylindrical granules made of pressed wood whose combustion is controlled by an electronic control...

Page 8: ...cause blockage of the auger and to stop the operation of the pellet stove IF PELLET STOVE BLOCKED THE REASON WILL APPEAR ON THE DISPLAY AND IT WILL BE SAVED Using low quality wood pellets or non manu...

Page 9: ...lue gases to safe for human health altitude over the area of habitation It is recommended that the pellet stove can be installed as close as possible to the chimney in order to reduce the number of co...

Page 10: ...eat consumers 10 Three way mixing valve thermostatic 11 Stopcock 12 Filter 13 Manometer 6 bar 14 Built in circulation pump The installation hydraulic diagram is indicative and does not replace the doc...

Page 11: ...ig 3 This operation must be repeated in the first days of use and when the system is recharged even partially The presence of air in the heating system can aggravate proper operation of the pellet sto...

Page 12: ...and then it would disappear in this case one can sure that the value has been saved correctly Just in case during the time of saving access to the Back Icon is denied to prevent involuntary interrupt...

Page 13: ...Fan Should one chose Turns then the fan would transfer to Set the Power Mode Should one chose Flow then the Fan would transfer to Flow Supervise Mode Mode of operation Here Heating Mode is firmly fix...

Page 14: ...imer ON shall not be active The delayed start is an autonomous one time timer which one can set a particular date and hour on to start the fireplace Its effect is a one time individual one The third o...

Page 15: ...can be locked in two ways The first one is to hold for more than 3 seconds the Title Page Settings Icon The second one is automatically while transitioning to Standby Mode of the Display in 10 minute...

Page 16: ...an to operate at 100 in Clean Mode This mode gets active if the contol unit transfers to switch off and extinction of the fireplace 600sec Period Here one cans et the time from 100 to 1000 seconds in...

Page 17: ...Start Mode In this mode what happens is the so called initial clean which lasts 60 seconds by default The smoke fan is set on maximum speed to clean the ashtray If we would like we can change the tim...

Page 18: ...are on Modulation 5 on pressing the selection field it will redirect to Modulation Change Menu It is important to note that this change is permanent It is saved and on restarting the control unit and...

Page 19: ...pump Check sensors Clean check and remove all debris from the ignition system Clean and check the electronic control system Check all electrical cables Clean the pellet fuel hopper and check auger to...

Page 20: ...given icon Exhaust gases High temperature of the combustion chamber above380 0 To remove the alarm the temperature has to drop below this value The stove continues to work Exhaust gases High temperat...

Page 21: ...in accordance with current regulations and laws Operation Well dried and of good quality wood pellets Diameter of 6 mm and maximum moisture content of 8 Chimney connecting flue pipes and combustion ch...

Page 22: ...ellet stove is designed to work with wood pellets with a diameter of 6 mm The use of another type of fuel leads to damage SPARE PARTS CATALOGUE Denomination Denomination 1 Gear motor for auger 17 Fire...

Page 23: ...02 2020 INSTRUCTION MANUAL for installation and operation of pellet stoveVITTORIA 23...

Page 24: ...Victoria 05 Ltd 24...

Page 25: ...internal contact with fire or hot surfaces Pellet stove is equipped with safety components that guarantee lock it automatically in case of failure of any of its components Safety components are activ...

Page 26: ...ease contact you dealer Any warranty repair of the pellet stove is recorded in the diary of warranty Warranty of the pellet stove is NOT VALID in the following cases Quickly worn out components glass...

Page 27: ...02 2020 INSTRUCTION MANUAL for installation and operation of pellet stoveVITTORIA 27 DIARY for repairs under warranty Company Receipt date Type of repair Delivery date Carried out...

Page 28: ...Victoria 05 Ltd 1BIvan Momchilov Str 5100 Gorna Oryahovitsa Republic of Bulgaria phone 359 618 60282 E mail info v05 bg http www v05 bg...

Reviews: