02.2020
INSTRUCTION MANUAL
for installation and operation of pellet stove
VITTORIA В*
13
10.2.3.Main menu.
„Air Correction”, „Pellets Correction”
parameters what
is set is the percentage smoke fan power lag in
operation modes and pause (rest) during the operation
of the screw conveyor!
This can be set within the range of - 15% up to +15% for
both parameters!
„Power Limit”
parameter would be setting the level of
operation of the system – Modulations 5,4..... down to
1.
„Turn/ Flow rate”.
Here one can change the operation mode of the Smoke
Fan. Should one chose Turns, then the fan would
transfer to Set the Power Mode. Should one chose Flow,
then the Fan would transfer to Flow Supervise Mode.
„Mode of operation”.
Here Heating Mode is firmly fixed.
„Тhermostat”.
The Indoor Sensor can be either switched on or off.
„Internet”.
Here one can check if there is an WIFI Module
connected to the system.
The IP address, one should connect to, to introduce the
necessary settings.
ID number of the device.
Status, displays if the WIFI Module is connected.
- 0 no module
- 1 a module is present, but is not connected
- 2 a module is connected to the router.
„Languages”
Here there is a Control Unit Language shortcut key.
The system offers four languages: English, Bulgarian,
Dutch, and German.