![Victaulic 795 Series Installation And Maintenance Instructions Manual Download Page 8](http://html.mh-extra.com/html/victaulic/795-series/795-series_installation-and-maintenance-instructions-manual_1013487008.webp)
I-795/906
/ Installation-Ready
™
Knife Gate Valve
/ Installation and Maintenance Instructions
DIMENSIONS – WITH BEVEL GEAR OPERATOR
VALVE CLOSED
NOT INSTALLED
VALVE OPEN
INSTALLED
VALVE OPEN
INSTALLED
E
C
H
F
B
J
Nominal Size
in
DN
Dimensions – inches/millimeters
Weight
lbs
kg
B
C
E
F
H
J
10
11.22
1.75
19.00
7.50
68.50
16.00
465.00
DN250
284.9
44.5
482.6
190.5
1739.9
406.4
210.9
12
11.22
2.00
21.00
7.50
73.00
16.00
497.00
DN300
284.9
50.8
533.4
190.5
1854.2
406.4
225.4
I-795/906_8
REV_D