UG:119
Page 22
Specifications
Input Characterisitcs
Input Voltage
85 – 264V
AC
, 47 – 500Hz 100 – 380V
DC
Power Factor
0.99 at 115V
AC
; 0.95 at 230V
AC
Inrush Current
25A
PK
at 115V
AC
and 230V
AC
Ride-Through Time
>20ms at nominal line, full load
Power Fail
>3ms warning
Conducted EMI
EN55022 Class A; FCC Class A (Certain configurations meet B. Contact factory)
Surge Immunity
EN 61000-4-5 Installation Class 3, Performance Criteria B
(Temporary loss of output power may occur which is self recoverable)
Dielectric Withstand
Primary to Chassis GND = 2,121V
DC
Primary to Secondary = 4,242V
DC
Secondary to Chassis GND = 750V
DC
Ouput Characterisitcs
Line/Load Regulation
VI-200™ / VI-J00™: ±0.2% max.10% to full load
±0.5% max. No load to 10% load
Line Regulation
[f]
Maxi: ±0.20% max. to 0.3% max LL to HL, Full Load
Load Regulation
[f]
Maxi: ±0.1% No load to full load
VI-200/VI-J00
Set Point Accuracy
[f]
1% for standard voltages; 2% for special or adjustable voltages
Maxi Setpoint Accuracy
1% for standard voltages;
2% for special, adjustable voltages and 48V
DC
outputs
Ripple and Noise
0.15% or 10mV
P-P
, whichever is greater, 75% min. load
Output Trim Range
10 – 110% of nominal voltage Maxi modules
50 – 110% of nominal voltage VI-200 / VI-J00 modules
90 – 110% of nominal voltage VI-200 / VI-J00 modules 10 – 15V
Overcurrent Trip Point
105 – 125% of full load capability of VI-200 / VI-J00 modules
115% typical of full load capability of Maxi modules
Overvoltage Protection
115 – 135% on VI-200 on QPAC™ and FinQPAC™
Efficiency
80% typical
Output Power
PFC MegaPAC-EL™
PFC MegaPAC-HPEL™
1,600W at 230V
AC
2,400W at 230V
AC
1,200W at 115V
AC
[f]
1,200W at 115V
AC
[f]
[f]
Not to exceed an input current of 15A.