Installation
InStallatIon ConSIderatIonS
Install the FMC-TRM units as required using “best practice” procedures. The FMC-TRRM units
may be wall mounted using “best practice” procedures. To install the FMC-TRRM in the
FMC-RK
Card Cage, proceed as follows.
WarnInG:
Although the units are hot-swappable and may be installed without turning power off
to the rack, ComNet recommends that the power supply be turned off and that the rack power
supply is disconnected from any power source.
note:
Remove electrical connector before installing in card cage rack.
1. Make sure that the card is oriented right side up and slide it into the card guides in the rack
until the edge connector at the back of the card seats in the corresponding slot in the rack’s
connector panel. Seating may require thumb pressure on the top and bottom of the card’s front
panel.
CaUtIon:
Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the
card is seated against the
front of the rack.
WarnInG:
Unit is to be used with a Listed Class 2 or LPS power supply rated 9-12 VDC @ 1A.
I
MPortant SaFeGUardS:
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient. Therefore,
consideration should be given to installing the equipment in an environment compatible with the
maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air
flow required for safe operation of the equipment is not compromised.
│FMC-TRM/TRRM Series Installation and Operation
4