Installing the V1501WM
The V1501WM is required for wall mounting the monitor mounts. Be sure the area behind the wall of the
selected location is clear of obstacles such as steel beams, headers, pipes, electrical wiring, etc. that would
interfere with the installation. To mount the V1501WM, proceed as follows.
1. Select a solid wall surface of concrete, masonry, reinforced wood frame or steel girder construction.
Caution
: A single vertical stud in a wood frame wall is not adequate; there must be enough reinforced
wooden frame structure for all four mounting bolts to be seated.
2. In concrete or masonry, mount the V1501WM with 5/16-inch lag screws and lead anchors. In wood, drill
four (4) pilot holes of 7/32-inch diameter according to the mounting hole pattern on the mount and use
5/16 x 2-1/2 lag screws. Refer to Figure 1. In steel, drill 11/32-inch holes and use 5/16-inch machine
screws and nuts. Use lock washers in all cases.
3. Proceed with monitor mount installation. After assembling the monitor to the monitor mount, attach the
mount to the wall mount with the 1/2-inch bolt, washer, and lock washer supplied. The large neoprene
washer must be inserted around the 1/2-inch bolt between the monitor mount and the wall mount.
Figure 1
V1501WM Wall Mount
X984-03-00 Rev 1105 Monitor Mounting Kits