Technical Information
Standalone: 24 VAC.
Rack Mount: power supplied
from card cage.
Transmitter: 375 mA.
Receiver: 330 mA.
Transmitter: 5.6 W.
Receiver: 5.0 W.
Transmitter: 0.321 btu/min
(0.08 kg-cal/min).
Receiver: 0.282 btu/min
(0.07 kg-cal/min).
Note: These figures represent
the conversion of 100% of the
electrical energy to heat. Actual
percentage of the heat
generated will be less and will
vary from product to product.
These figures are provided as
an aid in determining the extent
of cooling required for an
installation.
FCC Class A.
4.
Frequency Modulation (FM).
NTSC and PAL
10
MHz.
800 TV lines.
75 ohms.
1 V p-p nominal, composite
video.
1 V p-p.
3°.
5%.
55 dB.
100 ft (30 m) (video equipment
to transmitter or receiver).
Recommended cable type:
RG59/U coaxial cable (Belden
no. 9259 or
equivalent).
1300 nm.
12 dB (62.5
μ).
Power Requirements:
Current:
Power Consumption:
Heat Equivalent:
Radio Emission
Standard:
Number of Channels:
Modulation Type:
Formats Supported:
Video Bandwidth:
Horizontal
Video Resolution:
Video Input/
Output Impedance:
Video Input Signal:
Video Output Signal:
Differential Phase:
Differential Gain:
Signal-to-Noise Ratio:
Interconnection
Distance
(recommended):
Optical Wavelength:
Maximum Optical
Attenuation (Loss
Budget):
50 or 62.5
μ.
3.1 mi (5 km) on 62.5
μ cable.
Standalone: 3-pin Phoenix.
Rack Mount: connector in rack.
BNC.
ST type.
Video, power and optical
presence bi-color/green LEDs.
Standalone
Height: 1.1 in. (28 mm) .
Width: 8.9 in. (226 mm).
Depth: 5.5 in. (140 mm).
Rack Mount: 2 slots.
Standalone: 1.5 lb (0.7 kg).
Rack Mount: 0.8 lb (0.4 kg).
Aluminum.
Standalone: Silver.
Rack Mount: Black paint.
No. 8 (3 mm) hardware, 4
places.
Standalone
Height: 3.5 in. (89 mm).
Width: 8.3 in. (211 mm).
Depth: 14.5 in. (368 mm).
Rack Mount
Height: 3.1 in. (77 mm).
Width: 7 in. (178 mm).
Depth: 10.2 in. (259 mm).
Standalone: 3 lb (1.4 kg).
Rack Mount: 1.2 lb (0.5 kg).
Standalone
:
0.2 ft
3
(0.006 m
3
).
Rack Mount: 0.13 ft
3
(0.004 m
3
).
-40 to 165° F (-40 to 74° C),
noncondensing.
Up to 95%, relative.
-40 to 185° F (-40 to 85° C)
Fiber Type:
Maximum Transmission
Distance*:
Power:
Video:
Optical:
Diagnostics Indicators:
Dimensions:
Weight:
Construction:
Finish:
Mounting:
Shipping Dimensions:
Shipping Weight:
Shipping Volume:
Operating
Temperature Range:
Humidity Range:
Storage
Temperature Range:
ELECTRICAL
VIDEO
CONNECTORS AND INDICATORS
MECHANICAL
ENVIRONMENTAL
OPTICAL
*
Pending optical cable loss.