background image

 

 
 

Figure 1 

Mounting Plate Dimensions 

Camera Installation 

 

1.  Disengage the two (2) side latches to open the cover. 

2.  Remove the camera mounting plate from the housing by loosening the four (4) Phillips head screws used 

to secure the plate. Slide the plate off the screws using the key slot holes. 

3.  Mount the lens to be used on the camera according to the appropriate instruction manual. 

Note: When positioning the camera/lens combination, make sure that the lens is fully extended (the shortest 

focusing distance yields the greatest physical extension). Certain zoom lenses may have to be rotated 
90° on the camera to fit into the V9315H. 

4.  Select the location in the camera mounting slot which allows installation of the camera/lens with 1/4-in. 

(6.4 mm) of space between the lens and the window. Then mount the camera to the mounting plate with 
the supplied 1/4-20 screw, flat washer and lock washer. 

5.  Place the camera and plate back into the housing in a position where the lens just clears the window for 

the greatest angle of view. 

6.  Tighten the four (4) mounting plate screws to secure it in place. 

4  

 Installation 

X486-03-01 Rev 204 V9315H 

Summary of Contents for V9315H Series

Page 1: ...s subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 516 952 CCTV 2288 FAX 516 951 CCTV 2288 TOLL FREE 800 645 9116 UK 44 0 1489 566300 WEB www vicon cctv com Vicon part number 8006 8486 03 01 Section 7 Rev 204 ...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ... Inspection 3 Inspection For Visible Damage 3 Inspection For Concealed Damage 3 Mounting the Housing 3 Camera Installation 4 Wiring the Unit 5 Operation 7 Maintenance 7 Shipping Instructions 8 Technical Information 9 X486 03 01 Rev 204 V9315H Contents i ...

Page 6: ...List of Figures Figure 1 Mounting Plate Dimensions 4 Figure 2 Wiring Diagram 6 ii List of Figures X486 03 01 Rev 204 V9315H ...

Page 7: ...oduct should follow Vicon s instructions and a mounting accessory recommended by Vicon should be used 9 Ventilation Slots and openings in the cabinet are provided for ventilation and to ensure reliable operation of the video product and to protect it from overheating and these openings must not be blocked or covered The openings should never be blocked by placing the video product on a rug or othe...

Page 8: ...in a risk of fire or electric shock 17 Object and Liquid Entry Never push objects of any kind into this video product through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the video product 18 Servicing Do not attempt to service this video product yourself as opening or removing covers may expo...

Page 9: ...er plus a 120 VAC heater The V9315HC HS 230 includes a transformer and a 230 VAC heater The V9315H HS 24 includes a 24 VAC heater Additionally two heater options are available Model V8315H H 120 VAC and V8315H H 24 24 VAC for those installations where the V9315HC S was installed and heater were later required Model V9315H is used throughout this manual to refer to all versions of the housing unles...

Page 10: ...NOTES 2 Introduction X486 03 01 Rev 204 V9315H ...

Page 11: ... inspect the damaged equipment If the equipment must be returned for repair follow the Shipping Instructions at the end of this manual Mounting the Housing Be sure the area around the selected location is clear of obstacles such as steel beams headers pipes electrical wiring etc which would interfere with the mounting of the housing and that the location can support the combined weight of the enti...

Page 12: ... extended the shortest focusing distance yields the greatest physical extension Certain zoom lenses may have to be rotated 90 on the camera to fit into the V9315H 4 Select the location in the camera mounting slot which allows installation of the camera lens with 1 4 in 6 4 mm of space between the lens and the window Then mount the camera to the mounting plate with the supplied 1 4 20 screw flat wa...

Page 13: ...nals on the terminal board and tighten screws Refer to Figure 2 Wiring Diagram For 120 VAC and 230 VAC units connect the two 2 wires provided in the accessory kit from the camera to TB1 Connect the branch ground wire to the ground lead with a wire nut Route all power limited wiring away from non power limited wiring The wiring spacing between two different voltages e g 120 VAC and 24 VAC or coaxia...

Page 14: ...Figure 2 Wiring Diagram 6 Installation X486 03 01 Rev 204 V9315H ...

Page 15: ...vidual camera and lens for operation Maintenance The housing needs no maintenance other than the occasional cleaning of the window using plain soap and water Do not use abrasive cleaners which scratch the window surface X486 03 01 Rev 204 V9315H Operation 7 ...

Page 16: ...reham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete description of the problem and circumstances under which it occurs f Unit s original date of...

Page 17: ... will vary from product to product These figures are provided as an aid in determining the extent of cooling required for an installation Connector Screw terminal strip supplied for connections to AC line Transformer A 24 VAC transformer is provided for camera power in 120 and 230 VAC units OPTICAL Light Loss through Window Negligible OPERATIONAL Horizontal Adjustment Adjustable camera platform an...

Page 18: ... in H 102 x 74 mm Cable Access Two liquid tight compression fittings located at bottom of rear base Camera Access Two latches on left side of housing Housing Mounting Seven 1 4 20 tapped holes provided on bottom for mounting and balancing two screws must be used Adjustable fore and aft ENVIRONMENTAL Operating Temperature Range 30 to 120 F 34 to 49 C Moisture Rainproof elastomer seals and gaskets W...