  Introduction 

X819-03-01 Rev 102 V896MA Mounting Adapter 

Introduction 

The information in this instruction manual covers the installation of Model V896MA Mounting Adapter for the 
V896MSH Maximum Security Housing. This unit should only be installed by a qualified technician using 
approved materials in accordance with national, state and local codes. Read this manual through completely 
before attempting installation. 
 
The V896MA Mounting Adapter is used when the V896MSH Maximum Security Housing is to be mounted to a 
vertical surface, like a wall or square pole. Before installing the V896MA, refer to Instruction Manual X795 for the 
installation of the V896MSH housing and observe all Notes, Cautions and Warnings listed there. 
 

Installation 

To mount the V896MA, follow the steps below. Refer to Figure 1. 

Note:

 Be certain that the area behind the selected mounting location is clear of obstacles (such as studs, 

electircal wiring, pipes, etc.) which would interfere with the mounting of the unit. Video, power, and control 
cables should be routed to the selected mounting location. 

 

Caution:

 Mount this unit to structural materials with sufficient strength to carry the weight of the entire 

system, including housing and camera. Do not attempt to mount to drywall material or to a single 
2 x 4-inch wall stud. 

1.  Position the mounting adapter upside down (with mounting holes and cable holes facing up) on a table. 

Allow the mounting flange at the end of the adapter to overhang the edge of the table in order to permit the 
adapter to lie horizontally and not be tilted. 

2.  Remove the ten (10) Phillips flat head screws securing the housing base plate to the housing. 
 
Two rectangular gaskets are supplied with the V896MA Mounting Adapter. If the housing is to be installed 
outdoors or in a location subject to heavy moisture, use these gaskets in the installation as described below. 
Units mounted indoors in dry areas do not require the gaskets. 

3.  Place the appropriate gasket on the mounting adapter, taking care to align the mounting screw holes. 

Position the housing base plate over the adapter, aligning the holes in the housing, gasket and mounting 
adapter. Refer to Figure 2. 

4.  Make holes through the gasket on the housing base plate and fasten the housing base plate to the 

mounting adapter with six (6) 10-32 screws, flat washers and lock washers from the mounting adapter 
accessory pack. 

5.  Reattach the housing base plate and mounting adapter to the housing with the ten (10) screws previously 

removed. 

6.  Refer to Instruction Manual X795 and install the camera. 

7.  Lightly tape or glue the gasket that corresponds to the mounting flange on the mounting adapter into place 

to make the next mounting procedures easier. 

8.  Refer to Figure 3 or use the mounting adapter itself as a template. Mark and drill the holes for the mounting 

hardware and cut a cable routing hole. 

Summary of Contents for V896MA

Page 1: ... reserved Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 TOLL FREE 800 645 9116 24 Hour Technical Support 800 34 VICON 800 348 4266 UK 44 0 1489 566300 INFOFAX 800 287 1207 WEB www vicon cctv com ...

Page 2: ......

Page 3: ...X819 03 01 Rev 102 V896MA Mounting Adapter Introduction 3 ...

Page 4: ...dapter upside down with mounting holes and cable holes facing up on a table Allow the mounting flange at the end of the adapter to overhang the edge of the table in order to permit the adapter to lie horizontally and not be tilted 2 Remove the ten 10 Phillips flat head screws securing the housing base plate to the housing Two rectangular gaskets are supplied with the V896MA Mounting Adapter If the...

Page 5: ...nd into the housing Secure the cables by tying a knot in each one so that they cannot slip back through the cable access holes 11 Fasten the mounting adapter securely to the wall or square pole using four 4 1 4 inch min hardware If the mounting surface is steel of other structural metal use 1 4 20 bolts nuts and lock washers If the mounting surface consists of wooden beams use 1 4 inch lag bolts a...

Page 6: ...6 Installation X819 03 01 Rev 102 V896MA Mounting Adapter Figure 1 Exploded View ...

Page 7: ...A Mounting Adapter Maintenance 7 Figure 2 Figure 3 Housing Base Plate Gasket Dimensional Drawing Maintenance Model V896MA does not require any maintenance Refer to Instruction Manual X795 for maintenance of the V896MSH housing ...

Page 8: ...s in Europe contact Vicon Industries U K Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete description of the problem and cir...

Page 9: ...CAL Mounting Four 1 4 inch hardware appropriate for mounting surface Type Wall or pole mounting of V896MSH housing Application Indoor Outdoor Cable Access Hole provided for routing cable Dimensions Height 6 63 in 16 8 cm Width 3 0 in 7 6 cm Weight 2 9 lb 1 3 kg Construction Steel Finish Dark gray ...

Page 10: ...rope Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 322 712 8780 Fax 322 712 8781 Far East Office Unit 5 17 F Metropole Square 8 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...

Reviews: