Vicon V8612H Instructions For Installation And Operation Manual Download Page 3

rI

 

 

 

r

 

   

 

 

 

 

 

 

   

 

   

 

   

Solid line denotes
area to be cut out.

Dashed line indicates

 of mounting flange.

 FRONT

Six mounting holes
0.187 in. (0.47 cm)
in diameter

 

 

Figure 2

Ceiling Cutout

3.

Insert the supplied grommets into the 

appropriate

cutouts.

4.

Assemble and adjust camera and lens as described
in the camera/lens instruction manuals.

NOTE: Extend the camera lens fully when posi-

tioning the camera in the housing (shortest focusing

distance yields the greatestphysical extension). This

prevents interference between the lens and the hous-

ing window when the camera is in use.

5.

Mount the camera on the mounting bracket using a

 screw and lockwasher.

6.

Lift the unit (housing on ceiling panel) up to the

ceiling. Position the unit in the ceiling and thread

the cables through the cable openings in the
housing.

 

7.

Connect the video and electrical cables and energize

the camera.

8 .

Assemble and position the installation gauge in the

housing. Tape the gauge to the ceiling to provide a

reference plane for lens positioning.

9. Observe the scene on a monitor and adjust the

camera mounting bracket for the desired viewing

angle. Use the gauge as a guide to lens position.

NOTE: For detailed information on camera con-

nections and adjustments, refer to the appropriate
camera instruction manual.

10. Check all hardware for tightness. Close and lock the

cover.

1 1 . Cover the adjustment slots on the sides of the hous-

ing with a piece of duct tape to protect the housing
from dust entry.

X568-893

Reviews: