background image

4  

••

  Installation 

X618 Rev 1298 V8400H-17-HT Housing Accessories 

4.  Insert the brown heater thermostat wires from the component side through the upper opening (Legend 2 on 

Figure 1). 

5.  Attach the heater thermostat clip with the 6 x 1/4-inch self-tapping screw and snap the thermostat into the 

clip (Figure 2). 

 

Note: If the blower is to be installed, also mount the blower thermostat at this time. Refer to 

Installing the 

V8400H-B Blower

 on page

 

5. 

 

 

 

Figure 2 

Rear End Cap (Component Side) 

 

6.  Reattach the terminal board with the two (2) screws. 

7.  Connect the heater thermostat wires as shown in the wiring diagram, Figure 3. 

8.  Attach the heater plates to the four (4) studs on the bottom of the platform, using washers and nuts (Figure 

2). 

9.  Insert wires through the appropriate opening (Legend 2 on Figure 1).  Wire to terminal board as shown in 

Figure 3. 

 

Summary of Contents for V8400H-17-HT

Page 1: ...moisture Copyright 1998 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDU...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ...Accessories Contents i Contents Introduction 1 Installation 3 Installing the V8400H H Heater 3 Installing the V8400H B Blower 5 Installing the V8400H DEF Defogger 6 Jumper Wire Assembly 7 Shipping Ins...

Page 6: ...List of Figures Figure 1 Rear End Cap Wiring Side 3 Figure 2 Rear End Cap Component Side 4 Figure 3 Wiring Diagram for the V8400H Housing 5 Figure 4 Location of Defogger Assembly 6 Figure 5 Wiring the...

Page 7: ...aerosol cleaners 6 Attachments Do not use attachments not recommended by Vicon as they may cause hazards 7 Water and Moisture Do not use this video product in any location where it may be exposed to w...

Page 8: ...verload wall outlets and extension cords as this can result in a risk of fire or electric shock 17 Object and Liquid Entry Never push objects of any kind into this video product through openings as th...

Page 9: ...H 230 respectively The thermostat is preset to activate heaters at temperatures below 40 F 4 C and to turn off automatically when temperatures rise above 50 F 10 C Model V8400H B Blower is an interna...

Page 10: ......

Page 11: ...ccessible disconnect device is required to be incorporated into the site wiring To install the heater assembly proceed as follows 1 Release the two 2 latches at the rear end cap of the housing Slide o...

Page 12: ...blower is to be installed also mount the blower thermostat at this time Refer to Installing the V8400H B Blower on page 5 Figure 2 Rear End Cap Component Side 6 Reattach the terminal board with the t...

Page 13: ...2 Insert the red blower thermostat wires through the lower opening in the end cap Legend 2 3 Attach the blower thermostat clip with the 6 x 1 4 inch self tapping screw and snap the thermostat into th...

Page 14: ...mera mounting plate by inserting the screws provided into the two 2 fasteners on the bottom of the heater plate Refer to Figure 4 Figure 4 Location of Defogger Assembly 2 Insert the 23 inch lead from...

Page 15: ...ries Installation 7 Jumper Wire Assembly To provide power to the terminal board for accessories install jumpers as shown in Figure 6 Figure 6 Jumper Wire Connections Note The V8400H H V8400H B and V84...

Page 16: ...es in Europe contact Vicon Industries U K Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following informatio...

Page 17: ...AC Current A Power Consumption W VA Heat Equivalent btu min cal min Weight lb kg V8400H H 120 0 5 60 3 4 0 9 0 4 0 18 V8400H H 24 24 2 5 60 3 4 0 9 0 4 0 18 V8400H H 230 230 0 25 60 3 4 0 9 0 4 0 18 V...