INSTALLATION
Installation Considerations
This fiber-optic link is supplied in two forms, as a stand-
alone module and as a rack card. Units should be installed
in dry locations protected from extremes of temperature
and humidity.
Standalone Modules
1. Determine where the module is to be installed and
ensure that there is adequate space at both ends for
making the various cable connections and for reading
the diagnostic LEDs.
2. Standalone modules are provided with mounting holes
for four No. 6 screws (3-mm or 3.5-mm screws). The
type of screw chosen must be suitable for the surface
on which the module is to be mounted.
Rack Cards
Rack cards are designed to be installed in one of Vicon’s
19-inch (483-mm) EIA standard card-cage racks, either the
V515R-PS or the V517R-PS.
CAUTION:
Although a rack card may be installed
without turning off power to the rack (hot-swappable),
Vicon recommends that the power switch on the rack power
supply is turned OFF and that the rack power supply is dis-
connected from any power source.
1. Make sure that the card is oriented right-side up and
slide it into the card guides in the rack until the edge
connector at the back of the card seats in the corre-
sponding slot in the rack’s connector panel. Seating
may require thumb pressure on the top and bottom of
the card’s front panel.
CAUTION:
Take care not to press on any of the
LEDs.
2. Tighten the two thumb screws on the card until the front
panel of the card is seated against the front of the rack.
3
DIGITAL FOUR-CHANNEL VIDEO SYSTEM
FIGURE 3: STANDALONE MODULE, V707T AND V707R
OPTICAL
CONNECTOR
VIDEO 1
CONNECTOR
POWER
CONNECTOR
PIN 1
VIDEO 2
CONNECTOR
VIDEO 3
CONNECTOR
VIDEO 4
CONNECTOR
VIDEO TEST PATTERN SELECT (S1)
(LOCATED ON REAR OF MODULE)
ENABLE
DISABLE
1
2
ON
NTSC
PAL
Power Connections
Pin
Connection
1
+12 – 16 VDC
2
24 VAC
3
24 VAC
4
Ground