![Vicon V662-D-2 Installation And Operation Manual Download Page 21](http://html1.mh-extra.com/html/vicon/v662-d-2/v662-d-2_installation-and-operation-manual_1013108021.webp)
21
CONTROL AND CONNECTIONS/
DAY&NIGHT IN/ALA
RM OUT TERMINALS
1. Terminal Block (Option)
1-1. DAY&NIGHT EXTERNAL INPUT (1pin)
Switch the camera
’
s D/N mode to either Day or Night based on the input status. Refer to the
diagram below. The cameras D/N mode must be set to EXT for this to function.
Open contact: DAY
Close contact: NIGHT
1-2. Common/Ground
–
Used for D/N and Alarm connections.
1-3. ALARM OUT
- TTL level
Motion detection signals are output through this port. Active state is Low (GND).
Normal: Open Collector, ALARM: Low (GND).
1-4/5. CAMERA CONTROL
2. POWER INPUT TERMINAL
~ AC 24V ~
In DC power, use the Adapter mode than DC 12V 500mA capacity.
AC 100-240V
It is recommended to use a DC power supply that can support
inrush current over 0.55A.
AC Power Cord -
Power cord accepts a 100-240V ~ 60(50)Hz
±
1Hz
.
3. VIDEO OUT CONNECTOR
BNC: BNC connector provides a 1.0Vp-p/75 ohms composite video signal.
(Option)
GND
2
1
(GND)