Vicon V402 Series Instructions For Installation And Operation Download Page 2

GENERAL

The 

 Illuminator may be mounted on Vicon

medium- or heavy-duty pan and tilt drives or

scanners, and may be installed permanently on

walls, poles, or horizontal surfaces using
Vicon wall- or pedestal-mounts. See Figure 1,

 Mounting Plate.

The unit should be installed in such a way as

to achieve uniform illumination over the
entire area to be observed. Since light
energy diminishes with the square of the
distance from the illuminator to an object,
uniform illumination will not be attained if
there is too great a difference in the
distance between the illuminator and the

objects to be observed. Therefore, the
illuminator should be positioned at
approximately equal distances from the main
objects of interest in the area.

FIXED MOUNTING

The illuminator may be mounted on any firm

horizontal surface. The underside of the
illuminator is provided with two 
mounting holes. (See Figure 2.) It is also
provided with a centrally located mounting
slot which can be used for mounting the
illuminator on any Vicon wall or pedestal
mount. Use a 

 bolt to mount to these

units.

When the unit is mounted, aim it directly at
the scene to be illuminated and tighten the
mounting hardware.

*PAN AND TILT MOUNTING HOLES

**SCANNER AND CAMERA/HOUSING MOUNTING HOLES

Figure 1

 Mounting Plate

SPLIT

PLATE

LINE CORD 

(6 4 

I

Figure 2

 Mounting Diagram

2

X301 -686

Summary of Contents for V402 Series

Page 1: ...mp which is supplied with the illuminator is suitable for use with lenses of 50mm or longer focal lengths For lenses having focal lengths from 12 5mm to 25mm an optional wide beam lamp can be used Model V402 IRW These illuminators are controlled automatically by a photocell The photocell monitors the available light and energizes the unit when the illumination falls below a predetermined level Pro...

Page 2: ...be observed Therefore the illuminator should be positioned at approximately equal distances from the main objects of interest in the area FIXED MOUNTING The illuminator may be mounted on any firm horizontal surface The underside of the illuminator is provided with two l 4 20 mounting holes See Figure 2 It is also provided with a centrally located mounting slot which can be used for mounting the il...

Page 3: ...with the camera s line of sight as follows First loosen the two hex head bolts on either side of the illuminator mounting bracket Then tilt the illuminator up or down until the brightest area of illumination is at the center of the scene To align the horizontal axis loosen the central screw Use this screw as a pivot and swing the illuminator horizontally until the brightest area of illumination is...

Page 4: ...from the projected light beam clear day This setting can later be adjusted for individual needs or for the sensitivity of the particular camera being used The photocell circuit has a 30 second minimurn time delay feature This prevents false switching due to temporary flashes of light from car headlights temporary cloud darkening etc The illuminator will be on when it is first installed so avoid lo...

Page 5: ...filter only with nonabrasive window cleaner and a soft cloth SHIPPING INSTRUCTIONS If a unit must be returned to the factory follow these dlrec tions Call or write Wcon for Return Authorlzatlon R A at one of the followlng locatlons VICON INDUSTRIES INC 525 Broad Hollow Road Melvrlle New York 11747 5 16 293 2200 600 6459116 VICON INDUSTRIES INC Central Regional Office 400 Bonnre Brae Street River F...

Reviews: