4
•
Installation
XX211-21 Rev 1210 V15CCM-IR-2 Series High-Security Cell Cameras
Installation
The wall/ceiling material must provide suitable strength to support the weight of the unit (3.5 lb/1.6 kg). Be
sure the area around the selected location is clear of obstacles (such as steel beams, headers, pipes,
electrical wiring, etc.) that would interfere with mounting. All cables must be routed to the installation location.
Verify that the accessory pack contains the items listed in Table 2.
Item Quantity
Function
No. 20 Torx Bit
1
Use to remove and install tamperproof
screws from front plate
No. 10 Torx Bit
1
Use to remove and install tamperproof
screws from front plate access cover plate
2-Pin Terminal Block
1
Use to make power cable connections
Back Cover
1
Fire barrier;
required for Canadian UL
compliance
Quick Guide/Documentation CD/
ViconNet CD (IP versions)
1
Installation and operation instructions;
ViconNet setup CD
Table 2: Accessory Kit
Mounting the Housing
The housing consists of two main assemblies, the camera mounting frame and the removable front plate,
where the camera and all electronics are mounted. The front plate is secured to the base plate with Resistorx
tamperproof screws. A special bit is supplied in the accessory pack for removing and replacing these screws.
When the installation is complete, retain the Torx bit in case access to the interior of the housing is required
later. Additionally, a rear cover is supplied for those installations requiring Canadian UL compliance or extra
protection from fire.
Installation without the rear cover:
1. Remove the front plate using the no. 20 Torx bit provided; retain the screws in a safe place. Using the
camera mounting frame as a template, mark the locations of the mounting holes on the three mounting
tabs (2 holes per tab). Open a hole in the wall or ceiling to accommodate routing the cables to the
camera.
2. Route all necessary cables to the location if not already done so.
3. Drill suitable holes for the hardware selected appropriate for the wall/ceiling material. The use of No. 8 (or
4 mm metric) mounting hardware is recommended. Use hollow-wall anchors or, if the housing is being
mounted on a sheet metal surface, use rivet nuts.
4. Secure the camera mounting frame to the wall/ceiling with fasteners appropriate for the mounting surface.
Route the cables through the access hole in the wall or ceiling.
5. When the camera mounting frame is secured to the surface, apply an epoxy security sealant around the
perimeter of the base plate where it meets the ceiling/wall. [Vicon recommends DynaPoxy™ EP1200
(US) or Arbokol 1025 (UK) or equivalent for this purpose.]
Installation with the rear cover:
Note: The installation corner must be sharp and clean; if necessary, clean any excess material from the
installation location.
1. Remove the front plate using the no. 20 Torx bit provided; retain the screws in a safe place.