background image

Biometric Kiosk 
User Manual 

 

 

 

 

11 

 

Figure 1-7

 

Surface mounting steps   

 

1

2

3

4

 

  

 

 

 

 

Silicone pad 

Turnstile steel plate   

Lock nut 

Pendant bracket  

Summary of Contents for V1111B-THM-TB

Page 1: ...ody temperatures detected by the kiosk should be subject to secondary evaluation methods including NCIT or clinical grade contact thermometer Document Number 8009 8300 45 00 Product specifications sub...

Page 2: ......

Page 3: ...moderate dangers which if not avoided may cause minor or moderate injuries Alerts you to risks Neglecting these risks may cause device damage data loss device performance deterioration or unpredictabl...

Page 4: ...thermal camera should be powered on for half hour so that the temperature measurement is normal powered on for more than 1 5 hours provides the best results The camera is designed for indoor installat...

Page 5: ...eview Interface 18 2 3 1 Live Video Interface Preview 18 3 Configuration Setting 19 3 1 Menu Tree Structure 19 3 2 Basic Information 21 3 3 System Setting 21 3 3 1 Time configuration 21 3 3 2 User Man...

Page 6: ...Biome Us 3 7 4 SMTP 33 3 8 UI Sound Settings 34 3 9 Thermal Parameters 37 3 10 Access Condition 38 3 11 Upgrade and Maintenance 41 4 Facial Database 44 4 1 Add Face 44 5 Capture History 51...

Page 7: ...kiosk is ideal for use in a wide range of applications such as building lobbies and school entrances Advantages 0 9 F 0 5 C measuring temperature detection accuracy Thermal response time of 100 milli...

Page 8: ...Us Appearance Instructions and Cable description Figure 1 1 Feature Callouts Thermal Sensor White Light LEDs IR LEDs Dual HD Cameras Temperature Measurement 7 Inch Display Temperature Remark Pendant...

Page 9: ...ion Remarks 1 RJ45 Network port Connect to Ethernet Does not support PoE 2 POWER Power Connect to 12 VDC 3 DOOR LOCK COM Connect to Access control COM Access control port When the door lock is trigger...

Page 10: ...ne 2 3 Connect to alarm device line 3 G GND 6 ALARM OUT Alarm out COM negative Alarm OUT Alarm out positive 7 IO RS 485 G GND P Connect to alarm light negative A RS485 port A For Future Use B RS485 po...

Page 11: ...rce in the surrounding area There should be nothing covering the forehead It is recommended to start to measure temperature 30 minutes after being powered on Please wait for 2 3 minutes before measuri...

Page 12: ...Biome Us 1 3 Dimensions Figure 1 4 Dimensions unit in mm 1 1 28 10 1 256 4 7 120...

Page 13: ...ust be mounted at a height that allows the capture of faces and detection of temperature for a wide range of people s heights with the distance of detection considered The graphic below set shows the...

Page 14: ...s the threaded section of the pendant through the hole Figure1 7 2 Screw the pendant nut onto the threaded section of the column and use a wrench or other tools to tighten the nut Figure1 7 3 Connect...

Page 15: ...Biometric Kiosk User Manual 11 Figure 1 7 Surface mounting steps 1 2 3 4 Silicone pad Turnstile steel plate Lock nut Pendant bracket...

Page 16: ...Biome Us Instructions for wall mounting Remove the bracket from the Biometric Kiosk 53 9 28 75 44 75 15 19 36 35 32 75 4 5 68 1 4 1 4 3 5 12 1 32 25 80 2...

Page 17: ...the wall Bracket should be installed at the recommended height Assemble the bracket to the wall according to the figure above Slide the kiosk onto the wall plate The kiosk will hang from the groove o...

Page 18: ...Biome Us 1 5 Packaging list Table 1 2 Package list No Item Quantity 1 Biometric Kiosk 1 2 Power supply 12 VDC 2A 1 3 Screw package 1 4 L hexagonal wrench 1 5 Bracket 1...

Page 19: ...open the login page as shown in Figure 2 1 The camera does have a DHCP option that can be enabled to allow the camera to find an IP address via a DHCP server refer to the Networking section of this m...

Page 20: ...he Logout button in the top right corner of the page If you have forgotten your password you can answer the security configuration questions to verify identity and then set a new password as shown in...

Page 21: ...sword 2 2 Modify the Password At Configuration System User Management interface the password can be modified as shown in Figure 2 5 Figure 2 5 User Management Choose the username from the user list an...

Page 22: ...ion and Capture History interfaces and logout as shown in Figure 2 7 Figure 2 7 Preview interface 1 Monitor the live video 2 Tabs for Configuration settings for the system video image alarm network se...

Page 23: ...Resolution Device ID Time Zone Rate Type Manufacturer Name Time Format Video Frame Rate Device Model NTP Timing Max Bitrate Device Series Number Manual Timing Average Bitrate Hardware Version User Ma...

Page 24: ...mal Parameters Access Conditions Panel UI Settings FFC Control Door Unlock Trigger Condition Show IP Show Infrared Image Enable Thermal Detection Language Thermal Parameters Enable Mask Detection Pane...

Page 25: ...ID view the device model device serial number hardware version web version thermal serial thermal SDK version as shown in Figure 3 1 Figure 3 1 Basic information 3 3 System Setting At System interface...

Page 26: ...eference and enter pertinent information Click Save to save the settings 3 3 2 User Management At Configuration System User Management interface user can modify the security questions and password as...

Page 27: ...anges Figure 3 4 Security questions Choose the questions and enter the answers if the password is forgotten you can use the security questions to verify identity and set a new password Click OK to sav...

Page 28: ...t Configuration System System Parameters interface set the parameters of system for Normal Settings including Attribute Settings Face Recognition Settings Local Storage Duration and Local Storage as s...

Page 29: ...Set the recognition interval milliseconds Setting method Drag the slider Local Storage Duration Enable local storage you can set the timing duration day Setting method Check Input the value from 1 to...

Page 30: ...sts Click Save to save the settings The device is restarted login again and the settings will take effect 3 5 Image Settings At Configuration Image interface user can set display settings wide dynamic...

Page 31: ...value increases the borders become clearer and the number of noise points increases Setting method Drag the slider Default value 50 Saturation Indicates the color saturation of an image As the value...

Page 32: ...Limit to enable the function as shown in Figure 3 10 Figure 3 10 Exposure settings page Face AE Exposure Settings Figure 3 11 Face AE settings page Other Figure 3 12 Other page 3 6 Alarm At alarm inte...

Page 33: ...ould connect the alarm IO output port to external alarm device first Figure 3 13 Alarm Output Settings Click Save to save settings 3 6 2 Alarm Notification Email At Configuration Alarm Alarm Notificat...

Page 34: ...e the alarm input Enable the function Choose the alarm input number depends on which alarm input port is used and the trigger mode Normally Open Normally Closed depends on the feature of alarm input d...

Page 35: ...as shown in Figure 3 16 Figure 3 16 TCP IP configuration interface You can check the enable DHCP to obtain parameters automatically or modify the parameter manually Click Save to save the settings 3 7...

Page 36: ...ngs You will need to login to the web using the new port after changing the port 3 7 3 Upload Service At Configuration Network Service Upload Service interface set the parameters of HTTP Upload Server...

Page 37: ...information and define email sender and recipients as shown in Figure 3 19 Figure 3 19 SMTP interface Table 3 3 SMTP Parameter Description SMTP Server Address The email server address SMTP Server Por...

Page 38: ...Biome Us 3 8 UI Sound Settings At Configuration UI Sound interface set the parameters of panel as shown in Figure 3 20 Figure 3 20 UI Sound interface...

Page 39: ...tion Enable no mask detection select picture settings and prompt sound settings The camera will display and broadcast the set pictures and voices when it detects mask is not worn as shown Figure 3 21...

Page 40: ...bottom of the UI page Show Measurement Area A blue frame of the display area appears on the UI interface to help the personnel choose a suitable standing position Show Facial Recognition Results Compa...

Page 41: ...igure 3 23 Entry Permitted Figure 3 24 Anti Spoofing detection Figure 3 25 Unrecognized person detection 3 9 Thermal Parameters At Configuration Thermal Parameters interface set the parameters of temp...

Page 42: ...o test the shutter of infrared Setting method Check Click to restart the shutter Thermal Parameters Set the unit of temperature min temperature max temperature thermal correction coefficient environme...

Page 43: ...Biometric Kiosk User Manual 39 Figure 3 27 Access condition interface...

Page 44: ...oor can be opened Mask Guest No need to register any person who is wearing a wear a mask can open the door Thermal detection Mask Only registered personnel who meet the temperature setting conditions...

Page 45: ...Manual 41 Figure 3 28 Wiegand input interface Figure 3 29 Wiegand output interface 3 11 Upgrade and Maintenance At Configuration Upgrade and Maintenance interface user can upgrade and maintenance as...

Page 46: ...e Language Change the language of web as shown in figure Reboot Click Reboot on the pop up window click OK Wait few seconds the device will restart Reset Reset the device click Reset device to factory...

Page 47: ...will go to login interface activate the device again Upgrade Browse to the local folder where the upgrade software is located click Upgrade to upgrade the device The upgrade process takes 1 10 minute...

Page 48: ...own in Figure 4 1 Click to edit the face database Click to delete database 4 1 Add Face At the Face Database interface user can add people to database one by one or import the face database as shown i...

Page 49: ...to unlock by password To delete persons from the list check the persons you want to be delete and click Delete Click Export to export the data to a local folder the status is shown as in Figure 4 3 F...

Page 50: ...arch person Click to modify the information as shown in Figure 4 5 Click OK to save the changes Figure 4 5 Modify personal information Click to delete the person s information the pop up window displa...

Page 51: ...ntials centrally from the VTS software The VTS software is used to synchronize the data from the VTS software to each of the kiosks on the system The following steps describe that function 1 From the...

Page 52: ...Biome Us 3 Click the at top left 4 Click the check mark in the Synch device and Synch library range Click Apply...

Page 53: ...Biometric Kiosk User Manual 49 5 After the process is finished the Device synchronization status will indicate completed 6 If the system indicates the Synch process failed click View log...

Page 54: ...will indicate the images do not meet the requirement Retake the image with a higher quality 8 Open the kiosk web browser the Facial library should be synchronized from the VTS If no facial data displa...

Page 55: ...ll show capture time FIG sheet mask temperature and the scanning result as shown in Figure 5 1 Figure 5 1 Capture History interface The temperatures that are normal will be green high temperatures wil...

Page 56: ...Biome Us Figure 5 2 Set detail time User can set the detailed time to search...

Page 57: ......

Page 58: ......

Reviews: