Before beginning installation of the parapet mount, run all necessary cabling to the location selected for the 
installation. Cables are routed up through the mount to the dome system. 
 

1.  Attach one wall bracket and the support bracket to the parapet surface using appropriate hardware for 

the material of the parapet. Be sure that the wall bracket is against the parapet surface and the support 
bracket is on top of the wall bracket, with the stop on the support bracket facing out from the parapet. 
Refer to Figure 1. 

2.  Attach the second wall bracket to the parapet in the selected location, using appropriate hardware. The 

suggested minimum distance between the wall brackets is 12.0 inches (30.5 cm). 

3.  Insert the cap supplied into the bottom opening of the parapet mount.  

4.  Place the parapet mount in the cutout contour of the wall brackets, align the wall bracket covers and 

secure with the 5/16-18 x 1 inch screws, lock washers and flat washers supplied. To prevent the parapet 
mount from spinning, secure it to the bottom wall bracket through the hole in the mount with the 5/16-
18x3 inch bolt, lock washer, flat washer, and nut provided. 

5.  Route the cables through the cap and up the mount to where the dome system is installed. Apply caulk or 

RTV sealant around entrance opening in cap. 

6.  Install the SurveyorVFT housing. Screw the housing directly onto the parapet mount. Use the pipe 

sealant to secure the fit and make it watertight. Refer to the instruction manual for installation of the 
domed housing for specific installation instructions.  

7.  To swivel the dome system out over the parapet, loosen the bolts just enough to allow movement and 

position the unit. Tighten the bolts to secure the mount into position. 

8.  For high vandalism areas, lock the Dome with the soft tip set screw supplied. 

 

Note:

 If the optional 5/16-18 x 3 inch bolt was installed, it must be removed to swivel the unit. 

 

 
 
 
 
 
 
 

XX138-10-01 Rev 1005 SVFT-UPM-1 Parapet Mount 

Installation  

  3 

Summary of Contents for SurveyorVFT SVFT-UPM-1

Page 1: ...n Industries Inc Surveyor is a trademark of Vicon Industries Inc Teflon is a registered trademark of E I duPont de Nemours Co Molykote is a registered trademark of Dow Corning VICON INDUSTRIES INC 89...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ...rapet or similar structure The parapet mount provides a sturdy installation capable of withstanding extreme weather conditions It allows the mounted equipment to be swiveled onto the roof for easy ser...

Page 6: ...urveyorVFT Camera Dome Refer to the appropriate product specifications for the weights of these dome systems Be sure that the mount is installed in a location that can support the load There should be...

Page 7: ...secure with the 5 16 18 x 1 inch screws lock washers and flat washers supplied To prevent the parapet mount from spinning secure it to the bottom wall bracket through the hole in the mount with the 5...

Page 8: ...Figure 1 SVFT UPM 1 Installation 4 Installation XX138 10 01 Rev 1005 SVFT UPM 1 Parapet Mount...

Page 9: ...enough to allow movement Swing the unit in from the parapet Tighten the bolts After servicing or adjustment is complete loosen the bolts position the mount and tighten bolts Maintenance The SVFT UPM 1...

Page 10: ...5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the V...

Page 11: ...m Dimensions Height 37 in 940 mm Width 27 in 686 mm Construction Mount aluminum pipe 1 9 in 48 mm O D Braces and supports steel Hardware stainless steel Finish White paint ENVIRONMENTAL Wind Withstand...

Page 12: ...pe Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32 2 71...

Reviews: