![Vicon SurveyorVFT SVFT-UPM-1 Installation & Operation Manual Download Page 7](http://html1.mh-extra.com/html/vicon/surveyorvft-svft-upm-1/surveyorvft-svft-upm-1_installation-and-operation-manual_1013084007.webp)
Before beginning installation of the parapet mount, run all necessary cabling to the location selected for the
installation. Cables are routed up through the mount to the dome system.
1. Attach one wall bracket and the support bracket to the parapet surface using appropriate hardware for
the material of the parapet. Be sure that the wall bracket is against the parapet surface and the support
bracket is on top of the wall bracket, with the stop on the support bracket facing out from the parapet.
Refer to Figure 1.
2. Attach the second wall bracket to the parapet in the selected location, using appropriate hardware. The
suggested minimum distance between the wall brackets is 12.0 inches (30.5 cm).
3. Insert the cap supplied into the bottom opening of the parapet mount.
4. Place the parapet mount in the cutout contour of the wall brackets, align the wall bracket covers and
secure with the 5/16-18 x 1 inch screws, lock washers and flat washers supplied. To prevent the parapet
mount from spinning, secure it to the bottom wall bracket through the hole in the mount with the 5/16-
18x3 inch bolt, lock washer, flat washer, and nut provided.
5. Route the cables through the cap and up the mount to where the dome system is installed. Apply caulk or
RTV sealant around entrance opening in cap.
6. Install the SurveyorVFT housing. Screw the housing directly onto the parapet mount. Use the pipe
sealant to secure the fit and make it watertight. Refer to the instruction manual for installation of the
domed housing for specific installation instructions.
7. To swivel the dome system out over the parapet, loosen the bolts just enough to allow movement and
position the unit. Tighten the bolts to secure the mount into position.
8. For high vandalism areas, lock the Dome with the soft tip set screw supplied.
Note:
If the optional 5/16-18 x 3 inch bolt was installed, it must be removed to swivel the unit.
XX138-10-01 Rev 1005 SVFT-UPM-1 Parapet Mount