Sector No.
Up to 8 programmable sectors can be set using the joystick.
Sector ID
To set SECTOR ID, select up to 16 characters by moving the joystick to the left or right. Press the Zoom In
button to move to the next character from the left to the right and the Zoom Out button to move to the next
character from the right to left (space displays when
□
appears).
Sector Start
To set SECTOR START angle, press the AI button and then move the joystick to the left or right to set the
position. Press the AP button when setting the parameters is complete.
Sector End
To set SECTOR END angle, press AI button then move joystick to the left or right direction to set the end
position. Press the AP button when setting the parameters is complete.
Save
After setting the SECTOR position, save the data by moving the joystick to the right when the cursor is on
SAVE. After saving the data, the cursor moves to SECTOR NO. 2 automatically to define the next sector.
Exit
To escape this page, move the joystick to the right.
Exit
To escape the OSD Main Menu, move the joystick to the right or left. This camera is now set up and ready to
operate.
XX183-01-02 Rev 808 S10-CH Camera Dome System
•
19