X897-01 Rev 1205 NOVA V1466A
System Diagnostics
•
75
Test Alarm Port
Connections to and operation of the V1200X-IA alarm interface may be tested using the Alarm Port
Diagnostics screen. These tests do not apply to the V1300X-IA alarm interface.
Menu Path: Main Menu
→
System Diagnostics
→
Video Switcher and Titling Test
→
Front Panel Test
→
System Diagnostics Menu
→
Test Alarm Port
ALARM PORT DIAGNOSTICS
MAKE A SELECTION OR
PRESS ESC TO EXIT
1) TEST INPUT PORT
2) TEST OUTPUT PORT
Test Input Port
To check the X-IA alarm port’s ability to receive signals from the alarm interface devices, the Input Port Test
activates all alarm indication LEDs on the V1200X-IA alarm interface device(s). Press Enter and observe the
LEDs (they should illuminate for an active alarm). Check the alarm device(s) and connections to the V1466A
if any discrepancies are found.
Menu Path: Main Menu
→
System Diagnostics
→
Video Switcher and Titler Test
→
System Diagnostics
→
Test Alarm Port
→
Test Input Port
PRESS ENTR TO CONTINUE
PRESS ESC TO CANCEL
INPUT PORT TEST
ALARM PORT DIAGNOSTICS
OBSERVE XIA ALARM LEDS
FOR AN INDICATION OF
POINTS IN ALARM
Test Output Port
To check the X-IA alarm port’s ability to send signals to the V1466A CPU, the Output Port Test activates all
alarm indication LEDs on the V1200X-IA alarm interface device(s). The switches on the V1200X-IA must be
enabled. Press Enter and observe the LEDs (they should illuminate for an active alarm). Check the alarm
device(s) and connections to the V1466A if any discrepancies are found.
Summary of Contents for NOVA V1466A
Page 2: ......
Page 17: ...X897 01 Rev 1205 NOVA V1466A Preliminary Operations 6 This page intentionally left blank...
Page 39: ...X897 01 Rev 1205 NOVA V1466A Keypad Receiver 28...
Page 93: ...X897 01 Rev 1205 NOVA V1466A Install Defaults 82 This page intentionally left blank...
Page 97: ...X897 01 Rev 1205 NOVA V1466A Error Messages 86 This page intentionally left blank...