XX112-04-01 Rev 307 Kollector Elite Hybrid Network Digital Video RecorderCoaxial Cable Recommendations
•
21
Chapter 8
Coaxial Cable Recommendations
CAUTION: Careful selection of proper cable is essential to obtain the best performance from this
equipment. Vicon assumes no responsibility for poor performance when cables other than
those recommended, or equivalent, are installed. In all cases, coaxial cable impedance should
be 75 ohms.
Materials
Use only a pure copper center conductor. Do not use a copper-plated steel or aluminum center conductor, as
they will result in poor quality video. Solid-core bare copper conductor is the best type, where flexing and
bending will be minimal. If severe bending and flexing is required for installation, use a stranded center
conductor. Never exceed the manufacturer’s minimum bend radius specification. Use cellular (foam)
polyethylene dielectric except where heavy moisture exists. For moisture conditions, use solid polyethylene
dielectric cable with a heavy exterior insulation. The shield must be copper braid providing 95% or better
coverage.
Cable Types
The cable types listed below are the most common 75-ohm types used. They vary in size (diameter),
dielectric type and net DC resistance. The larger cable results in a lower DC resistance and better video
quality, with increased difficulty in handling and installation. Let the required picture quality and cable distance
provide a guide in choosing the best cable type. For cables other than the approved Vicon types below,
contact the manufacturers listed below. Note that “BC” refers to bare copper and “TC” refers to tinned copper.
Table 8-1: Recommended Coaxial Cable Types
Cable
Type
Belden
Type No.
Alpha
Type No.
West Penn
Type No.
Type Center
Conductor
Type Shield and %
Coverage
DC Resistance
ohms/1000 ft
(km)
RG-11/U 8213 9847 811,4811 14
Solid
BC
BC braid (95%)
2.6 (8.5)
RG-6/U
9248
9804C
806,4806
18 Solid BC
Foil + 61% TC braid (100%)
7.5 (24.6)
RG-59/U
8281*
----
815
20 Solid BC
2 TC braids (96%)
9.9 (32.5)
RG-59/U
9259
9803
816
22 Stranded BC
BC braid (95%)
15.0 (49)
RG-59/U 9659
----
---- 22
Stranded BC
BC braid (95%)
15.0 (49)
*Requires special BNC-M connector due to 0.305 nominal O.D.
Belden Inc.
http://www.belden.com/
(800) 235-3361
Alpha Wire Company
http://www.alphawire.com/
(800)-52 ALPHA (522-5742)
West Penn Wire
http://www.westpenn-cdt.com/
(800)-245-4964