Vicon part number 8009-8243-00-00   Rev 0112 

Page 1

INSTALLATION AND OPERATION MANUAL 

CE-(X)COAX

EthErnEt-OvEr-COAX EXtEndEr  

with PAss-thrOugh POE

The CE-(X)COAX Ethernet over COAX line consists of four models that support  

100 Mbps Ethernet as well as pass-through Power over Ethernet (PoE) over standard 

75Ω coaxial cable. These models support transmission distances of up to 

 

5,000 feet (1524 m) at 10 Mbps, or 1800 feet (548 

m) at 100 Mbps. The CE

-1COAX, 

the CE-4COAX, CE-8COAX and the CE-

16COAX transport, one, four, eight or sixteen 

channels respectively. The IEEE 802.3-compliant extenders also meets the requirements 

for IEEE 802.3af/at PoE power, passing through up to 30 watts of power per port to the 

powered device (PD). The CE

-(X)COAX series may also be used interchangeably with 

other Ethernet-over-Coax extenders. 

Environmentally hardened to the requirements of NEMA TS-1/TS-2 for most out-of-plant 

applications, and true plug-and-play design ensures ease of installation and operation. 

LED indicators are provided for rapidly ascertaining the operating status of the device. 

See Figure

s 7 and 8 on page 6

 for LED explanations.

Packaged in a rugged aluminum housing, these units are designed for desktop or stand-

alone mounting. The 

CE-8COAX and CE-

16COAX are offered in EIA 19” 1U high rack for 

easy installation. See Figures A through C on 

page 7

 for mounting instructions.

See Figures 1 – 

8

 for complete installation details. 

important safety warning:

Read and keep these directions
Heed all warnings

Follow all instructions

Do not use this apparatus near water
Clean only with a dry cloth

Install in accordance with the 

manufacturer’s instructions
This installation should be made by a 

qualified service person and should conform 

to all local codes

See further safety instructions on pa

ge 8

Summary of Contents for CE-4COAX

Page 1: ...er Coax extenders Environmentally hardened to the requirements of NEMA TS 1 TS 2 for most out of plant applications and true plug and play design ensures ease of installation and operation LED indicators are provided for rapidly ascertaining the operating status of the device See Figures 7 and 8 on page 6 for LED explanations Packaged in a rugged aluminum housing these units are designed for deskt...

Page 2: ...no power supply connected to the unit it will try to detect PoE FIGURE 1 CE 1COAX FIGURE 3 CE 4COAX FIGURE 2 CE 1COAX INSTALLATION AND OPERATION MANUAL CE X COAX LEFT PANEL RIGHT PANEL LEFT PANEL 10BaseT 100BaseT 12 3 4 10BaseT 100BaseT 12 34 Note Center pin on power connector is positive Tech Support 800 34 VICON 800 348 4266 ...

Page 3: ...pply Ground Screw 12V Power Supply Ground Screw FIGURE 4 CE 8COAX FIGURE 5 CLFE16COAX INSTALLATION AND OPERATION MANUAL CE X COAX Tech Support 800 34 VICON 800 348 4266 COAX 75Ω COAX 75Ω COAX 75Ω COAX 75Ω COAX 75Ω COAX 75Ω CAT5 6 CAT5 6 CAT5 6 CAT5 6 CAT5 6 CAT5 6 ...

Page 4: ...E 16UTP PoE Switch 328 ft 100 m Cat 5 CE 4US1TPC IP Cameras IP Cameras Single Port Copper over Coax NVR PoE Switch 5 000 ft 1524 m Coax 328 ft 100 m Cat 5 CE 1COAX CE 1COAX PoE Camera Multi Port Copper over Coax NVR CE 16COAX PoE Switch 5 000 ft 1524 m Coax 328 ft 100 m Cat 5 CE 1COAX PoE Camera 3 000 ft 914 m Cat 5 5 000 ft 1524 m Coax Copper Managed High Power Midspan NVR CE 16IPS Switch Data Po...

Page 5: ... DIP switch to Local mode Set the S1 10 100BaseT DIP switch to the appropriate rate based on the maximum data rate OFF 10BaseT ON 100BaseT Be sure the S2 switch to is set to Off for Slave Note The 4 8 and 16 channel units are preset to Slave Local mode No adjustment required Connect the 12 VDC or 24 VAC power supply to the power connector of the selected CE X COAX If there is no external power sou...

Page 6: ...DICATORS FIGURE 8 RJ 45 LED INDICATORS POWER TRAFFIC Extended 10 100BaseT GREEN Connection is OK 10BaseT mode YELLOW RED Power is on Flashing Traffic present Connection is OK 100BaseT mode OFF Power is off No traffic RJ 45 TRAFFIC Standard Link GREEN Flashing Connection is OK with traffic YELLOW Connection is OK RED OFF No connection No connection ...

Page 7: ... 95 mm 3 6 92 mm 17 432 mm 1 6 40 mm 3 3 84 mm 1 6 40 mm 1 75 44 5 mm 3 25 82 5 mm 1 6 40 mm 1 15 30 mm Tech Support 800 34 VICON 800 348 4266 Installation Considerations The CE 1COAX and CE 4COAX are supplied as standalone modules The CE 8COAX and CE 16COAX can be installed as standalone modules or can be rack mounted with the addition of the provided 19 inch rack mounting ear brackets MECHANICAL...

Page 8: ...cluding DVRs that produce heat Protect the power cord from being walked on or pinched particularly at the power source convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer Unplug this apparatus during lightning storms or when unused for long periods of time Refer all servicing to qualified service personnel Servicin...

Reviews: