Replacing the Battery 

Warning: 

Before replacing the 

battery, turn off the Apex.  

To replace the battery: 

1.

To remove the battery 

compartment cover, squeeze the 

back of the handle         and push 

it towards the inside of the Apex. 

 

2.

Remove the old battery.   

3.

Place the new battery into the 

battery holder.  

4.

Replace the battery compartment 

cover on the inside of the handle 

and ensure it is snapped shut. 

5.

Turn on the Apex and run it until 

the battery is flat. To speed up 

this process, connect to the 

device in Tracker and enable 

Continuous Mode

 in the 

Properties pane

 as described in 

the following section, 

Using an 

Apex with Vicon Tracker

 

6.

Fully recharge the Apex (see 

page 3).  

This enables it to calculate the 

battery life. 

7.

To order replacement batteries, 

email 

[email protected]

01 

01 

 

3.

In the Properties pane, you can 

change the name of the selected 

device, alter the delay 

compensation, adjust the  

brightness of the LEDs, and enable 

the LEDs to be on continuously, 

instead of being strobed.  

You can also cause the handle of 

the selected device to vibrate by 

clicking 

Identify

Tip

: Use of 

Continuous Mode

 

causes the battery to be 

discharged more quickly than using 

strobe mode. To reduce power 

consumption, select 

Sleep,

 and use 

the 

Sleep Timeout

 controls to 

specify the number of minutes of 

inactivity after which the device 

will turn off the tracking LEDs. 

When you touch the joystick or 

buttons, the LEDs are reactivated. 

4.

To enable Tracker to remember the 

device that you have added for 

future sessions, save the current 

configuration using the 

configuration management controls: 

 

 

Warning:

 This product contains a 

lithium ion battery. 

Do not incinerate the battery. 
Do not disassemble the battery. 
Do not short the battery 

terminals. 
Do not expose the product or 

the battery to high 
temperatures (140

°

F/60

°

C). 

Using an Apex with Vicon Tracker 

Important:

 To enable Apex and 

Tracker to communicate, you must 

use the supplied Bluetooth dongle 

with the standard Microsoft 

Bluetooth stack and drivers on  

the PC. 

To use an Apex with Tracker: 

1.

Charge the Apex and switch it on 

in the capture volume. 

2.

To ensure th

at

 the standard 

Microsoft Bluetooth stack and 

drivers are installed on the PC, 

plug the supplied Bluetooth 

dongle into the PC and restart  

the PC. 

3.

Start Tracker. 

4.

To add the Apex to the current 

configuration, in the 

System

 list, 

right-click 

Other Devices

 and then 

click 

Add Apex Device

5.

In the 

Add Apex Devices

 dialog box, 

select the device and click 

Add

 
To change Apex properties: 

1.

In the System list, make sure the 

required Apex is selected. 

2.

To see all the settings, if 

necessary, at the top right of the 

Properties pane, click Show 

Advanced: 

 

Summary of Contents for Apex

Page 1: ...Vicon Apex User Guide Reliable Responsive Precise ...

Page 2: ...on 06 Battery charge indicator LEDs two red two amber one green 07 Battery charging status LEDs 08 Buttons configurable 09 Bluetooth LEDs In first illustration top right the right LED illuminates when device is connected the left LED illuminates while awaiting connection and then flashes when the device is connected to indicate data traffic 10 Camera strobe sensors 03 10 02 06 07 08 09 08 09 02 05...

Page 3: ...n the Apex is connected to a charger the battery charging status LEDs indicate the battery s current charging status Amber Green Status Off Off Not charging no connection On Off Charging Off On Charge complete On On Replace battery To charge the battery 1 Plug in the supplied Apex battery charger Note To charge the Apex you can use the supplied adaptor or any micro USB to USB 2 0 adaptor 2 Insert ...

Page 4: ... select Sleep and use the Sleep Timeout controls to specify the number of minutes of inactivity after which the device will turn off the tracking LEDs When you touch the joystick or buttons the LEDs are reactivated 4 To enable Tracker to remember the device that you have added for future sessions save the current configuration using the configuration management controls Warning This product contai...

Page 5: ...ations However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the sep...

Page 6: ...pment RoHS The Vicon Apex hardware is fully RoHS compliant The European Union Directive 2002 95 EC provides that new electrical and electronic equipment put on the market for the first time from 1 July 2006 shall not contain more than permitted levels of lead cadmium mercury hexavalent chromium polybrominated biphenyls PBB or polybrominated diphenyl ethers PBDE Waste Electrical and Electronic Equi...

Page 7: ...MOTION SYSTEMS LIMITED has tested and demonstrated that the product meets 2004 108 EC and 1999 5 EC Electromagnetic Compatibility to EN60601 1 2 2007 and EN301489 17v2 1 1 EN301489 1v1 8 1 EN 61000 6 2 2005 R TTE Compatibility to EN300328v 1 7 1 EN301 893 v 1 4 1 ERC 99 23 DFS TPC General Requirements for Safety to EN60601 1 2006 R TTE Health Requirement article 1 a referring to EN50371 2002 Thoma...

Page 8: ...he trademarks of their respective owners Vicon Motion Systems is an OMG plc company Contacts For further information contact your nearest Vicon office or email info vicon com facebook com vicon twitter com _vicon youtube com vicon100 Vicon Motion Systems UK registered no 1801446 Denver 7388 S Revere Parkway Suite 901 Centennial CO 80112 USA T 1 303 799 8686 F 1 303 799 8690 Los Angeles 3750 S Robe...

Reviews: