background image

HOURS

1

2

3

4

5

6

7

11

8

9

10

12

8

9

1.  

Power:

 With the Power Knob in the OFF position ( O ), plug humidifier into a polarized  

120V outlet.

 

 CAUTION: TO AVOID ELECTRIC SHOCK DO NOT PLUG HUMIDIFIER INTO OUTLET  

 WITH 

WET 

HANDS.

2. 

Output: 

Turn the Power Knob clockwise to highest setting. 

3.  

Position humidifier to direct mist output away from walls, furniture and bedding.  Mist Outlet 
can rotate 180° and is removable for cleaning. 

4. 

 

Humidity Level:

 When a comfortable humidity level is reached, turn Power Knob to a lower 

setting. A comfortable humidity level is between 40-60%.   

 

CONDENSATION: If you notice condensation on the walls, windows or around unit,  
your humidity level is too high. Turn humidifier off and open door to room.

To monitor your humidity level, use a humidity monitor such as the Vicks Humidity Monitor  
(V70) available at retailers or at www.vickshumidifiers.com.

Note: 

Auto shut off feature will activate when water runs out of the Tank or the Tank is removed 

from the unit.  The auto shut off will not turn off the Power Knob light; it will just turn off the fan  
and nebulizer.

 Step 2

 Step 4

 Step 3

 Step 1

VapoPads

®

 Recommended Usage:

• Not recommended for infants under 10 lbs (4.5 kg).

• For children between 10-22 lbs (4.5-10 kg ) do not use more than 2 pads in a 24 hr period.

Scent Pad Ingredients: VSP-19, VSP19FP, VSP19VPC, VSP-19 CAN: Eucalyptus Oil, Menthol, 
Glycol,Cedar Leaf Oil & Others. 

Using Your Humidifier

 Step 1

Your EasyFill Cool Mist Humidifier can be used with Vicks VapoPads

®

, VSP-19 or VBR-5 series, to 

provide up to 8 hours of soothing vapors. One free sample of the methol VapoPad is included with 
your humidifier. To use your unit with scent pads:

1. 

Open Scent Pad Door.

2.  

Open Scent Pad by tearing notch on pad bag. 

Do not

 touch pad with hands. If pad is touched 

do not 

rub face or eyes as it may cause irritation.

3.  

Insert Vicks Scent Pad with angled end facing towards the product. Up to two scent pads can 
be inserted. Close door.

4. 

After 8 hours, discard scent pad.

To continue using scent pads, repeat steps 1-4.

Using Vicks

®

 VapoPads

®

 Step 3

 Step 2

 Step 4

How to Use

1. 

Turn off, unplug and remove Tank Cover. Empty Water Tank.

2.  

Empty Reservoir by slowly pouring from the low side of the Housing on the opposite side from 
the Mist Outlet and away from Power Knob. Wipe outside of housing to dry any water that  
may have escaped between Base and Housing.

3. 

Rinse Tank, wipe clean and dry with a soft cloth or paper towel.

4. 

Refill Water Tank with cool water according to 

Filling/Refilling the Water Tank

 instructions.

Note: 

Ensure Float Paddle remains installed correctly.  For detailed instructions, refer to  

Float Paddle Installation

 section.

   CAUTION: Improper placement of the Float Paddle could result in leaking or water  

 

not feeding into the Reservoir.

Daily Maintenance

 Step 2

 Step 4

 Step 1

MAX

 Step 3

10

11

 Step 2

 Step 3

 Step 1

1.5C

 Step 5

 Step 6

 Step 4

Cleaning Your Humidifier    

(Continued)

1. 

Pour a minimum of 2 cups (.5 liters) of undiluted distilled white vinegar in the Water Tank.  

 

Gently swish vinegar around in the Tank to wet entire inside of Tank. 

2. 

Place Tank on Base. Vinegar will drain into the Water Reservoir and loosen mineral buildup  

 

(scale) in the Reservoir and bottom of the Water Tank. There should be enough vinegar to  

 

cover the bottom of the Tank. If not using a dishwasher, the four removable components can  

 

be soaked in the Tank. Just add enough vinegar to cover the components in the Water Tank.

3. 

Soak for 20 minutes, then remove Water Tank and slowly empty vinegar into sink. Remove  

 

components placed in Tank. Rinse Tank and components with tap water until the smell of  

 

vinegar is gone.

4. 

Remove Float Paddle from Reservoir by lifting up on Float Rod and set aside.  

 

Wipe Nebulizer and Reservoir area with a soft cloth to remove loosened minerals. 

5. 

Empty vinegar from the Reservoir by slowly pouring from the low side of the Housing on the  

 

opposite side from the Mist Outlet and away from Power Knob. Pour 1.5 cups of water into  

 

Reservoir, lightly swish water and pour out. Repeat until smell of vinegar is gone.  Avoid  

 

getting water into any openings in the Reservoir area by pouring from the low side of the 

 

Housing on the opposite side from the Mist Outlet and away from Power Knob. 

  

CAUTION:  Do not submerge the Base in water. Doing so may damage the  

 

humidifier and void the warranty.

6. 

Place Float Paddle back in Reservoir, ensuring Float Rod is secured in brackets.   

 

For detailed instructions, refer to the 

Float Paddle Installation

 section.    

 

 CAUTION:  Improper placement of the Float Paddle could result in leaking or  

 

water not feeding to the Reservoir.

 

Wipe outside of housing to dry any water that may have escaped between Base and Housing.

V

2C

MINUTES

To

p

Le Haut

“Click”

MAX

M

A

X

Scale Removal

Follow steps 1-5 in 

Before Cleaning section

, then follow the additional steps below.

1. 

Turn off and unplug humidifier. Never clean the humidifier when it is running.

2. 

Remove Water Tank and Tank Cover. Empty water from Tank.  

3. 

Remove accessories, including Demineralization Cartridge, from the Tank if being used.  

 

Do not 

clean accessories.

4. 

Remove Mist Outlet, Outlet Cover, Mist Chamber, and Tank Cover. 

 

Note: 

These four components are dishwasher safe. They may be cleaned in the 

Top Rack

 of 

 

the dishwasher or by hand as noted in following instructions. 

Do not place in the bottom  

 

rack of dishwasher.

5. 

Holding the Base, empty water from Reservoir by slowly pouring from the low side of the 

 

Housing on the opposite side from the Mist Outlet and away from the Power Knob. 

The  

 

Float Paddle should remain firmly attached to the brackets in the Reservoir.

Cleaning Your Humidifier

To keep your humidifier running efficiently, clean it regularly. Weekly cleaning is recommended. All 
maintenance should be done in the kitchen or bathroom on a water resistant surface near a faucet. 

To properly clean your humidifier we recommend the separate processes of Scale Removal  
and Disinfecting.

 These two processes must be performed separately.

Before Cleaning

 Step 2

 Step 4

 Step 5

 Step 1

 Step 3

Do not clean

D

Cleaning Your Humidifier    

(Continued)

Cleaning Your Humidifier    

(Continued)

Reassembling

After descaling and disinfecting, follow these steps to reassemble the unit:

1.  

Replace Mist Chamber over Air Outlet. 

2. 

Place Outlet Cover on top of Mist Chamber and lightly press down until it clicks into place  

 

and sits fully seated on the Housing.

3. 

Place Mist Outlet into the recess in the Outlet Cover, lining up the opening in the Outlet 

 

with the circle graphic on the Outlet Cover. Press down until you hear a click. This ensures  

 

Mist Outlet is positioned properly.   

4. 

Ensure Float Paddle is installed correctly. Line up Float Paddle with the float paddle shape  

 

on the bottom of the Reservoir. Place Float Rod over both Brackets and press firmly  

 

until you hear it click into both Brackets. Pull gently up on the Float Rod to be sure it  

 

doesn’t pop out  of the Brackets.

   CAUTION:  Improper placement of the Float Paddle could result in leaking or water  

 

not feeding to the Reservoir.

5. 

Replace Tank Cover and place Tank back onto Base.

End of Season Cleaning and Storage 

Follow the cleaning instructions when the humidifier will not be used for at least one week, or at the 
end of the season. 

At the end of the season, remove any accessories and discard.  Allow the humidifier and all compo-
nents to dry completely before storing.

DO NOT

 store humidifier with water inside the Reservoir or Water Tank.

Pack unit safely and store in cool, dry location.

 Step 2

 Step 4

 Step 5

 Step 3

 Step 1

“Click”

To

p

Le Haut

MAX

MAX

“Click”

12

13

1.  

Mix 1 gallon (3.8 L) of water with 1 teaspoon of bleach. Pour the bleach solution into the Tank. 

 

Note: 

Using more than 1 teaspoon of bleach to 1 gallon (3.8L) of water may result in damage  

 

to the humidifier.

2.  

Place Tank on Base. Bleach solution will drain into the Water Reservoir. If not using  
a dishwasher, the Mist Outlet, Outlet Cover, Mist Chamber and Tank Cover can be soaked  
in the Tank. Just add additional bleach solution to cover the components in the Water Tank.

3. 

Soak for 20 minutes, then remove the Water Tank and slowly empty bleach solution into  

 

sink. Remove components placed in Tank. Rinse Tank and components with tap water until  

 

the smell of bleach is gone.

4. 

Remove Float Paddle from Reservoir by lifting up on Float Rod and set aside.   

5. 

Empty bleach solution from the Reservoir by pouring from the low side of the Housing on the  

 

opposite side from the Mist Outlet and away from Power Knob.  Pour 1.5 cups of water into  

 

Reservoir, lightly swish water and pour out. Repeat until smell of bleach is gone.  Avoid  

 

getting water into any openings in the Reservoir area by pouring from the low side of the  

 

Housing on the opposite side from the Mist Outlet and away from Power Knob.  

 CAUTION:  Do not submerge the Base in water. Doing so may damage the humidifier 

and void the warranty.

Wipe outside of housing to dry any water that may have escaped between Base and Housing.

 Step 2

 Step 1

(3,8 l)

B

1 tsp

W

1 Gal.

 Step 3

MINUTES

 Step 4

1.5C

 Step 5

MAX

MAX

Disinfecting

Follow steps 1-5 above in 

Before Cleaning

 section, then follow the additional steps below.

NOTE:

 Bleach may stain clothes. It is recommended that you wear rubber gloves during this process 

to protect your hands.

Problem

Possible Cause

Solution

Mist is coming out from 
bottom of Mist Outlet*

Mist Outlet not properly 
installed

 
Outlet Gasket is missing

Remove and replace Mist 
Outlet into the recess in the 
Outlet Cover and press down 
until you hear a click

Contact Consumer Relations

Outlet Cover will not sit 
securely on Housing 
when reassembling after 
cleaning

Outlet Gasket was removed 
for cleaning and not securely 
replaced in Outlet Cover

Be sure Gasket fits tightly in 
Outlet Cover

Mist is escaping from 
the area between the 
tank and housing, in 
addition to the mist 
outlet

Outlet Gasket is missing

Replace Gasket if it was 
removed for cleaning or 
contact consumer relations 
for a replacement

Humidifier shuts off

Water Tank is empty

Float Paddle is not installed 
properly

Fill the Tank with Water

Check that the Float Paddle  
is secured in Brackets

White Dust accumulating 
on surrounding surfaces

Using tap water in your 
humidifier in hard water areas

If using, Demineralization 
Cartridge has reached life 
expectancy

Use distilled water or 
use a Protec TWT500 
Demineralization Cartridge

Replace Demineralization 
Cartridge

Condensation on 
windows and walls or 
area around humidifier 
is damp

Mist intensity is set too high 
for room size or pre-existing 
humidity level

Humidifier may be too close 
to wall or window

Decrease mist output to a 
lower setting or open door  
to the room

Move humidifier away from 
wall or point Mist Outlet away 
from wall or window

14

15

Troubleshooting     

(Continued)

If your humidifier is not working properly, refer to the following:

Problem

Possible Cause

Solution

Water is not draining  
into Reservoir

Plunger is stuck 

Float Paddle not installed 
correctly 

Demineralization Cartridge not 
allowing water to flow

Push and release Plunger to be 
sure it is moving freely 

Check Float Paddle and ensure 
it is placed securely  
in brackets

Uninstall Demineralization 
Cartridge, shake a few times, 
and re-install

Power light is on but little  
or no mist is released

Water Tank is empty

Power Knob is set too low

 
Hardened minerals on  
the Nebulizer

Mist Chamber is not installed

Fill Water Tank

Turn the Power Knob clockwise 
(right) to increase output

Clean Nebulizer (refer to 
Cleaning instructions)

Verify that all components are 
installed properly

Water leaking from Base 
or Reservoir

Float Paddle not placed 
correctly

Plunger is damaged

Plunger is sticking

 
Tank is cracked

 
Plunger may have foreign 
material stuck under the  
Tank Gasket

Ensure Float Rod is secured  
in Brackets

Contact Consumer Relations

Push and release Plunger to be 
sure it is moving freely

Inspect Tank for damage; 
contact Consumer Relations

At sink, push and release 
Plunger system so water  
may flow.

Troubleshooting

If your humidifier is not working properly, refer to the following:

NOTE:

 Keeping this unit clean from mineral deposits normally contained in water supply will improve 

the efficiency and operation of this unit.

*

Note:

 It is normal to see some mist escape around the Mist Outlet when the unit first starts and the 

Mist Outlet is dry.

For additional troubleshooting help, call Consumer Relations at 1-800-VAPOR-1-2 (1-800-827-6712).

Reviews: