This humidifier adds water vapor to the surrounding air helping the user to breathe better. If you have 
any questions about the operation of your Vicks

®

 

EasyFill Cool Mist Humidifier, call our toll-free Consumer 

Relations line at 1-800-VAPOR-1-2 (1-800-827-6712) or e-mail us at [email protected].

Adjustable mist control

No filters to replace

Easy to clean

Easy

Fill

Cool Mist Humidifier

IMPORTANT! 

READ AND SAVE THESE INSTRUCTIONS

2

3

1.

  The humidifier should always be placed 

on a firm, flat, waterproof surface at least 
four feet (1.2m) away from bedside, 12 
inches (30 cm) from the wall and out of 
reach of patients, children and pets. Be 
sure the humidifier is in a stable position 
and the power cord is away from heated 
surfaces and out of the way to prevent the 
humidifier from being tipped over.

2.

 

  The humidifier should not be left 

unattended in a closed room since 

air 

could become saturated and leave 
condensation in front of unit, on walls 
and furniture.

 Leave room door partly 

open. 

Do not

 aim Mist Outlet directly at 

children, walls or furniture.

3.

   Before using the humidifier, extend the 

cord and inspect for any signs of damage. 

Do not

 use the unit if the cord has been 

damaged. 

Do not

 operate with power cord 

coiled or with twist tie in place.

4.

   The humidifier has a polarized plug (one 

blade is wider than the other) as a safety 
feature. This plug will fit into a polarized 
outlet only one way. If the plug does not 
fit fully into the outlet, reverse the plug. 
If it still does not fit, contact a qualified 
electrician. 

Do not

 attempt to defeat this 

safety feature.

5.

  

 CAUTION:

 To avoid fire or shock 

hazard, plug the humidifier directly into  
a 120V AC electrical outlet. To avoid risk  
of fire, shock or personal injury, 

do not 

 

use an extension cord or power strip.

6.

   The humidifier should always be unplugged 

and emptied when not in operation or 
while being cleaned. Shut off and unplug 
humidifier before moving. 

Do not

 move or 

tilt humidifier while it is in operation. Plug 
and unplug unit with dry hands. 

Never

 pull 

by cord.

7.

  

Do not 

operate the humidifier without 

water. Turn off and unplug unit when tank 
is empty.

8.

   Humidifier requires regular cleaning. Refer 

to and follow cleaning instructions.

9.

  

Do not 

operate outdoors; this humidifier is 

intended for indoor residential use only.

10.

  

Do not

 cover or insert objects into any 

openings on the unit.

11.

  

Do not

 block intake or output vents.

12.

  

Do not

 attempt to repair or adjust any 

electrical or mechanical functions on this 
humidifier. Doing so will void your warranty.  

13.

  

Do not

 place in direct sunlight, high 

temperature areas or near computers or 
sensitive electronic equipment.

14.

  

Do not

 touch the nebulizer while the unit is 

plugged in as burns could result.

15.

  

Do not

 touch skin with exposed VapoPad

®

 

or place VapoPad

®

 on furniture, fabric, 

bedding or plastic.

16.

  

Do not

 add any medications (e.g. Kaz 

Inhalant or Vicks VapoSteam

® 

or oils)  

into Mist Outlet, Base, Water Reservoir  
or Water Tank.

SAVE THESE INSTRUCTIONS

 Important Safety Instructions

READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS 

BEFORE USING THIS HUMIDIFIER

WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAUTIONS SHOULD ALWAYS  

BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK AND INJURY  

TO PEOPLE, INCLUDING THE FOLLOWING:

The following accessories work great with your humidifier: 

Accessories

Vicks VapoPads

®

(One Menthol VapoPad Sample Included)

Menthol scent: VSP-19, VSP19FP, VSP19VPC or VSP-19-CAN

Lavender/rosemary scent: VBR-5 and VBR-5FP (US only)

Use Vicks VapoPads with your humidifier for soothing vapors.  
Enjoy 8 hours of soothing comfort per pad. 

Protec Antimicrobial Cleaning Products

(Protec Cleaning Ball: PC1 and PC2 or Protec Cleaning Fish: PC1F)

The Protec Cleaning Products feature an antimicrobial, Aquastat

®

, that  

helps keep your humidifier cleaner, longer. Simply drop in the tank for  
fresh, clean mist!  Benefits of using these products include:

•  Kill up to 99% of odor causing bacteria 
•  Keep cleaning for 30 days 
• Contain no harmful chemicals

Protec

®

 Demineralization Cartridge (included in some models)  

(TWT500)

This humidifier works with a Demineralization Cartridge that helps remove  
minerals from the water. This helps prevent the build up of minerals  
(“white dust”) that can occur in hard water areas. If you live in a hard water  
area, we recommend the use of this demineralization cartridge if not using  
distilled water. For best results, replace your Demineralization Cartridge every  
20-30 fillings, or when you begin to notice white dust forming.  The effective  
time will vary depending on the mineral content of the water used.

Humidity Monitor  

(V70 or V70-CAN)

Displays relative humidity and room temperature so you can maintain  
a comfortable humidity level in your home. The ideal humidity level  
is between 40-60%.

Accessories available at retailers and at  www.vickshumidifiers.com.

4

5

Keep this instruction manual for reference.

1.

  Remove packaging materials. Locate 

Float Paddle

 and set aside. This is required for operation.

2.

  Locate the Demineralization Cartridge (included in some models) and set aside. This is  

 

optional for operation. 

3.

  Remove twist tie and extend power cord. Place on a firm, level, water resistant surface  

 

a minimum of 12 inches (30 cm) from walls. 

Float Paddle Installation – required for humidifier to operate

1.

  Remove Water Tank.

2.

  Line up Float Paddle with the float paddle shape on the bottom of the Reservoir.  

3.

  Place Float Rod over both Brackets and press firmly until you hear it click into both Brackets. 

4.

  Pull gently up on the Float Rod to be sure it doesn’t pop out of the Brackets.  

5.

  Replace Tank in Base.  

If using the optional demineralization cartridge, see next section 

Installing Demineralization Cartridge

.

This humidifier uses a float system to regulate the water flow from the Tank to the Reservoir. The Float 
Paddle must be properly installed for the unit to operate. If not properly installed, water may not flow into  
the Reservoir or it may leak from the Base. The Float Paddle is designed to be easy to install and remove.

 CAUTION:

 

Improper placement of the Float Paddle could result in leaking or water  

not feeding to the Reservoir.

 Step 2

 Step 3

 Step 1

Setting Up Your Humidifier

Unpack the Humidifier

Setting Up Your Humidifier     

(Continued)

To

p

Le Haut

 Step 2

 Step 5

 Step 4

MAX

MAX

 Step 3

To

p

Le Haut

“Click”

MAX

MAX

Float 

Rod

Float 

Paddle

Brackets

 Step 1

Hard Water and White Dust

High mineral content in your water, also known as hard water, may cause a white mineral residue to 
accumulate on surfaces in the room near the humidifier. This mineral residue is commonly referred to 
as white dust. The higher the mineral content (hardness) of your water, the greater the potential that an 
ultrasonic humidifier may produce white dust. 

White dust is not a result of a defect or flaw in the humidifier. It is a result of the amount of minerals 
suspended in the water you are using.

14

 

Demineralization 
Cartridge 

 

(included in some models)

15

 

Plunger

16

 

Tank Gasket

17

 

Float Paddle

18

 

Air Outlet

19

 

Water Reservoir

20

 

Nebulizer

1

 

Mist Outlet

2

 

Outlet Cover

3

 

Outlet Gasket

4

 

Tank Handle

5

 

Tank Opening

6

 

Tank Cover

7

 

Water Tank

8

 

Auto Shut-Off Float

9

 

Housing

10

 

Base

11

 

Power Knob

12

 

Scent Pad Door

 

13

 

Mist Chamber 

Components

MAX

MAX

10

1

3

2

4

9

7

6

5

15

14

12

 8

18

13

20

19

17

16

11

Vicks

®

 EasyFill Cool Mist Humidifier (Model VUL570)

Getting to Know Your Humidifier

How It Works

Water is released into the Reservoir when the Float Paddle engages the Plunger at the bottom of the Water 
Tank. A Nebulizer vibrates at ultrasonic frequency, breaking the water into a fine mist. The mist is quietly 
propelled by a fan up a vertical Mist Chamber to the Mist Outlet where the cool, visible mist enters the room. 
This humidifier will shut off when the water level is low or when the tank is removed from the base.  

1.  

Pour cool water from a pitcher or jug directly into Water Tank. 

2.  

Fill to the MAX line marked on the outside of the Tank or to the MAX indicator on the  
Tank Cover. Replace the Tank Cover if it was removed for filling.

Filling/Refilling The Water Tank    

(Continued)

1.  

Grasp Tank Handle and lift Water Tank to remove from Base. Carry Tank to sink. 

2. 

Fill Tank with cool water to the MAX line marked on the outside of the Tank or to the MAX  

 

indicator on the Tank Cover. Replace the Tank Cover if it was removed.  

NOTE: 

The Tank should be carried using two hands; one hand on the Handle located on top of the 

Tank and other hand supporting the bottom of the Tank. 

3.  

Carry Water Tank back to humidifier. 

4. 

Replace the full Tank on the Base. 

 CAUTION: Use care when handling Water Tank to avoid unnecessary impact. Banging 

or dropping the Water Tank could result in damage to the Tank that may cause leaking.

Option 2: To Fill Tank at the Sink

Option 1: To Fill Tank at the Humidifier

This humidifier holds a maximum of 1.25 gallons (4.7 liters) of water. 

The Tank Cover is removable. You can fill the Tank with the Cover in place or with the Cover removed.  
Be sure to replace the Cover before using the humidifier to keep objects and debris out of the water.

The Tank can be filled in two ways:

Option 1:  At the Humidifier      Option 2: At the Sink

Both filling options can be performed with or without the Tank Cover in place. 

Note:

 Ensure the Float Paddle has been placed correctly in the Reservoir before filling.  

See 

Float Paddle Installation

 instructions if necessary

Manufacturer will not accept responsibility for property damage caused by water spillage.

MAX

MAX

6

7

 Step 2

 Step 3

 Step 1

 Step 2

 Step 2

 Step 3

 Step 4

 Step 1

 Step 1

Installing the Demineralization Cartridge - (Optional)

If you live in a hard water area, the use of distilled water or a demineralization cartridge with tap water  
will help minimize the production of white dust. A Protec Demineralization Cartridge (Model # TWT500)  
is included in some models. To install it:

1.

 Remove 

Tank 

Cover. 

2.

  Press the Cartridge into the recessed area inside the Water Tank and twist to secure.    

3.

  Fill Tank with water according to instructions in the next section, 

Filling/Refilling the Water Tank

.

Note:

 

With a new, dry cartridge, there may be a delay of a few minutes while the water begins to 

pass through the cartridge.

For best results, replace your Demineralization Cartridge every 20-30 fillings, or when you begin 
to notice white dust forming. For your convenience, write the month and day you installed the new 
cartridge on the top with a permanent marker.

To replace, twist the Cartridge and lift to remove. Dispose of in household trash. Replace with a new 
Protec Demineralization Cartridge (Model # TWT500). (Not available in Canada).

Filling/Refilling the Water Tank

Setting Up Your Humidifier     

(Continued)

MAX

MAX

 Option 1

MAX

 Option 2

MAX

MAX

MAX

MAX

MA

X

MAX

M

AX

Reviews: