Troubleshooting

The following faults may be caused by wrong connection or operation, please
check according to the specified procedures:

Switch failure

1. Check if the power plug is well connected to the socket or if the charge
connector gets loose.

Solution: make sure the power plug or charge connector well connected
to socket.

2. The fuse may be melted down.

Solution: unplug the power cable, and use a “

”-shaped screw diver to

open the fuse box and check if the fuse is melted. If it is melted please
check if the speaker cable “+” and “-” contact. If not replace the melted
fuse with a new fuse of the same specifications.

No sound

1. Check if the pre amp and source are operating normally.

Solution: connect another power amp to see if the pre amp and source
are operating normally.

2. Check if the signal cable and speaker cable are well connected.

Solution: unplug the signal cable and plug it again until you hear “click”
sound. Check if the power amp and loudspeaker binding posts
connecting the speaker cable are well connected.

3. Check if the loudspeakers are operating normally.

Solution: connect another power amp to check if the loudspeakers are
operating normally.

Warnings: All the checks above can be done only when the main power

is switched off.

Summary of Contents for NS 160

Page 1: ...Owner s Manual...

Page 2: ...cturer 10 Be careful when moving this apparatus 11 Unplug this apparatus during lightning storms or when unused for long periods of time 12 When this apparatus needs repair please contact the dealer D...

Page 3: ...ree conductor mains cable for NS 160 and 2 for NS 380 If anything is missing please contact your VibratoTM dealer at your earliest convenience Place and Ventilation If you want place this apparatus on...

Page 4: ...160 NS380 are capable of producing breathtaking sound at a high power But your power supply may be a marring factor for the sound due to your listening habits or the number of speakers and amplifiers...

Page 5: ...eds necessary maintenance You have a 3 year free warranty Please read the warranty card for more information Note The voltage inside the machine is beyond safety standard And the integrated circuit is...

Page 6: ...in the apparatus goes into stand by mode In stand by mode the circuits and components inside need only low voltage to operate and the power consumption and heat generated are very little 2 Indicators...

Page 7: ...o switch off the main power before connect disconnect the signal wire 2 Speaker output connect this terminal to the speaker via high quality speaker cable Please notice the and polarization and the le...

Page 8: ...ou flip the button to position the apparatus goes into stand by mode Note the left and right power of NS380 are separate and you have to switch on the power on both sides to ensure both the left and r...

Page 9: ...it damaged or even transistors burned out If you convert to single ended input at your own risk any damage caused to the power amp or other connected units will be not covered by the warranty 2 Connec...

Page 10: ...remains on Power off Please first turn down the volume of the pre amp and press the switch key to turn off the indicator then power off the device Note in the audio system the power on procedure is s...

Page 11: ...cable and contact If not replace the melted fuse with a new fuse of the same specifications No sound 1 Check if the pre amp and source are operating normally Solution connect another power amp to see...

Page 12: ...nced terminal Audio output 2 pairs of WBT gold plated binding posts Dimensions WHD 450x170x475mm Weight 25kg NS 380 Output power 200W RMS channel 8ohms 380W RMS channel 4ohms Effective bandwidth 650kH...

Reviews: