background image

[email protected]  www.vibco.com

800-633-0032

WARNING: Failure to read and follow these installation instructions and safety precautions could result in personal injury, equipment damage, 

shortened service life or unsatisfactory equipment performance.  All information in this document is vital to the proper installation and operation 

of the equipment.  It is important that all personnel who will be coming in contact with this product thoroughly read and understand this manual.

INSTRUCTION

MANUAL

©2020 VIBCO, Inc.   IM_H_B-H_05020

B&H SERIES

HYDRAULIC

CANADA

2215 Dunwin Dr., Mississauga, Ont. L5L 1X1

For custom mounting 

applications or any other questions:

800-633-0032

or

[email protected]

11

HYDRAULIC CONNECTION H-SERIES

12

 

INITIAL START UP

Warranty

All warranty claims must be submitted to VIBCO for approval prior to any repairs being done. Failure to do so will void any and all warranty coverage. All repairs will be 

done at the VIBCO factory.

Errors, Shortages & Complaints

Complaints concerning goods received or errors should be made at once.  Claims must be made within five days after receipt of goods.  Clerical errors are subject to cor-

rection. Damage during shipping must be reported to the carrier, not VIBCO.

Returning Parts **

Parts should not be returned to VIBCO without prior authorization.  Call VIBCO’s customer service department at 800-633-0032 (800-465-9709 in Canada) for a Return 

Goods Authorization (RGA) number.  A return authorization will be emailed or faxed to you.  Use this as your packing slip.  Return shipping must be prepaid.  Material 

returned may be subject to a 10% restocking fee.  All returned shipments should clearly display your name, address and original invoice number to ensure proper credit.

** Orders for custom equipment built to customer’s specifications are not returnable.

Product Changes

VIBCO reserves the right to make changes in pattern, design or materials when 

deemed necessary, without prior notice or obligation to make corresponding changes in 

previous models. To be sure of exact mounting dimensions, it is recommended that you 

obtain a certified dimensional drawing from the factory.

Ordering Spare Parts

Parts can be ordered through authorized distributors or from VIBCO’s Spare Parts De-

partment. The following data should be provided when placing your spare parts order:

From label: 

 

Model number of unit.

From spare parts list:  Reference number, part number, description & quantity required.

Shipping instructions:  Specify shipping point and method of shipping.

1.  Coat all fittings with sealing compound and 

secure hydraulic hoses to inlet & outlet sides 

of motor as marked by directional arrows.

2.  Hook up flow valve on inlet side, check valve 

on outlet side & case drain hose back to 

reservoir.

3.  Check & tighten all fittings & connections 

before test running vibrator.

4.  Hydraulic system MUST have a filtration 

system & oil is industrial petroleum-based 

oil, SAE 10 to 30, with wear, oxidation and 

foaming inhibitors, and a viscosity of 200 SSU.

FROM

HYDRAULIC

PUMP

TO

RESERVOIR

CHECK VALVE

MUST be located 16” - 24” (400mm-

600mm) away from motor on outlet

line side

HYDRAULIC MOTOR

Inlet hose size MUST match size of inlet motor fitting & 

outlet hose size should be one size larger than outlet motor 

fitting & larger than inlet hose

CASE DRAIN

If outlet pressure exceeds 30psi or if 

return line is not a direct line from vibrator 

to reservoir, case drain hose to reservoir 

MUST be installed

THREAD SIZE

MODEL NUMBER

INLET

OUTLET

CASE DRAIN

HF-800, 1200, 1500

3/4 - 16 (SAE8)

3/4 - 16 (SAE8)

7/16 - 20 (SAE4)

HLF-700, 1300

9/16 - 18 (SAE6)

9/16 - 18 (SAE6)

7/16 - 20 (SAE4)

HF-HC-HLF-1750,

3500 , 5000 & HL-3000

3/4 - 16 (SAE8)

3/4 - 16 (SAE8)

7/16 - 20 (SAE4)

MAXIMUM

OIL TEMP.

150°F (65°C

)

DO NOT OVER TIGHTEN 

HYDRAULIC HOSE FITTINGS

ATTENTION:  

WHEN HOOKING UP MULTIPLE UNITS YOU MUST HOOK UP THE CASE 

DRAIN HYDRAULIC LINE.  UNITS WILL BECOME DAMAGED IF RUN IN SEQUENCE 

WITHOUT A CASE DRAIN HOOK UP BACK TO THE RESERVOIR. 

FLOW

CONTROL VALVE

MUST be located on 

inlet side of motor

ADDITIONAL DETAILS AVAILABLE ONLINE AT www.vibco.com

1.  Be sure steps 1-11 are complete before starting vibrator. Missing 

a step can cause vibrator failure & void warranty.

2.  Always check pressure to & from vibrator with a pressure gauge. 

If inlet pressure exceeds 1200psi (82 bar) or outlet pressure 

exceeds 30psi (2 bar) check for restrictive fittings or increase 

hose size. Be sure case drain is hooked up as a return to 

reservoir.  For Model’s B outlet should be directly connected to 

the oil reservoir and carry NO back pressure.

3.  Do a quick inspection of hydraulic oil.  If dark or thick, replace 

with new oil.

4.  Inspect structure for cracks or fatigue and repair if any are found.

5.  Run unit for 5-10 seconds & check all fittings for leaks.

WARNING! 

 

HYDRAULIC OIL UNDER PRESSURE CAN PENETRATE SKIN 

AND RESULT IN INJECTION POISONING.  IF OIL PENETRATES SKIN CONSULT 

WITH A DOCTOR IMMEDIATELY!

CHECK LINE PRESSURE

Always check pressure to & from 

vibrator with a pressure gauge. 

Insert gauge in-line with the vibrator 

before & after the inlet/outlet.

If inlet pressure exceeds 1200psi 

(82 bar) or outlet pressure exceeds 

30psi (2 bar) check for restrictive 

fittings or increase hose size.

INLET

PRESSURE

OUTLET

PRESSURE

13

MAINTENANCE

Check tightness of 

mounting bolts every 

200 hours or every 

month of operation.

Check tightness of 

all hydraulic hoses 

and connections.

Inspect hydraulic oil 

on a periodic basis. If 

dark or thick replace 

with new oil.

Check structure for cracking 

or fatiguing. If found, repair 

before running unit. Call 

VIBCO for instructions to 

repair fatigue cracking.

14

TROUBLESHOOTING

LEAKING OIL?

1.  Check tightness of all hydraulic fittings.

2.  Be sure the check valve is installed in the proper direction with the flow of 

hydraulic oil.

3.  Check outlet line pressure (panel 12). If outlet line pressure is over 30psi 

case drain hose to reservoir MUST be installed.

4.  End cover leaks on B-Series vibrator is a result of high oil pressure.  

Check castings for cracks & contact VIBCO immediately.

5.  If shaft seals are leaking on H-Series vibrator contact VIBCO for 

replacement kit & instructions. Shaft seal failure is due to excessive back 

pressure & case drain MUST be installed.

Use this handy 

QR Code 

to get any of our 

Product Catalogs

Reviews: