[email protected] www.vibco.com
800-633-0032
WARNING: Failure to read and follow these installation instructions and safety precautions could result in personal injury, equipment damage,
shortened service life or unsatisfactory equipment performance. All information in this document is vital to the proper installation and operation
of the equipment. It is important that all personnel who will be coming in contact with this product thoroughly read and understand this manual.
INSTRUCTION
MANUAL
©2020 VIBCO, Inc. IM_H_B-H_05020
B&H SERIES
HYDRAULIC
CANADA
2215 Dunwin Dr., Mississauga, Ont. L5L 1X1
For custom mounting
applications or any other questions:
800-633-0032
or
11
HYDRAULIC CONNECTION H-SERIES
12
INITIAL START UP
Warranty
All warranty claims must be submitted to VIBCO for approval prior to any repairs being done. Failure to do so will void any and all warranty coverage. All repairs will be
done at the VIBCO factory.
Errors, Shortages & Complaints
Complaints concerning goods received or errors should be made at once. Claims must be made within five days after receipt of goods. Clerical errors are subject to cor-
rection. Damage during shipping must be reported to the carrier, not VIBCO.
Returning Parts **
Parts should not be returned to VIBCO without prior authorization. Call VIBCO’s customer service department at 800-633-0032 (800-465-9709 in Canada) for a Return
Goods Authorization (RGA) number. A return authorization will be emailed or faxed to you. Use this as your packing slip. Return shipping must be prepaid. Material
returned may be subject to a 10% restocking fee. All returned shipments should clearly display your name, address and original invoice number to ensure proper credit.
** Orders for custom equipment built to customer’s specifications are not returnable.
Product Changes
VIBCO reserves the right to make changes in pattern, design or materials when
deemed necessary, without prior notice or obligation to make corresponding changes in
previous models. To be sure of exact mounting dimensions, it is recommended that you
obtain a certified dimensional drawing from the factory.
Ordering Spare Parts
Parts can be ordered through authorized distributors or from VIBCO’s Spare Parts De-
partment. The following data should be provided when placing your spare parts order:
From label:
Model number of unit.
From spare parts list: Reference number, part number, description & quantity required.
Shipping instructions: Specify shipping point and method of shipping.
1. Coat all fittings with sealing compound and
secure hydraulic hoses to inlet & outlet sides
of motor as marked by directional arrows.
2. Hook up flow valve on inlet side, check valve
on outlet side & case drain hose back to
reservoir.
3. Check & tighten all fittings & connections
before test running vibrator.
4. Hydraulic system MUST have a filtration
system & oil is industrial petroleum-based
oil, SAE 10 to 30, with wear, oxidation and
foaming inhibitors, and a viscosity of 200 SSU.
FROM
HYDRAULIC
PUMP
TO
RESERVOIR
CHECK VALVE
MUST be located 16” - 24” (400mm-
600mm) away from motor on outlet
line side
HYDRAULIC MOTOR
Inlet hose size MUST match size of inlet motor fitting &
outlet hose size should be one size larger than outlet motor
fitting & larger than inlet hose
CASE DRAIN
If outlet pressure exceeds 30psi or if
return line is not a direct line from vibrator
to reservoir, case drain hose to reservoir
MUST be installed
THREAD SIZE
MODEL NUMBER
INLET
OUTLET
CASE DRAIN
HF-800, 1200, 1500
3/4 - 16 (SAE8)
3/4 - 16 (SAE8)
7/16 - 20 (SAE4)
HLF-700, 1300
9/16 - 18 (SAE6)
9/16 - 18 (SAE6)
7/16 - 20 (SAE4)
HF-HC-HLF-1750,
3500 , 5000 & HL-3000
3/4 - 16 (SAE8)
3/4 - 16 (SAE8)
7/16 - 20 (SAE4)
MAXIMUM
OIL TEMP.
150°F (65°C
)
DO NOT OVER TIGHTEN
HYDRAULIC HOSE FITTINGS
ATTENTION:
WHEN HOOKING UP MULTIPLE UNITS YOU MUST HOOK UP THE CASE
DRAIN HYDRAULIC LINE. UNITS WILL BECOME DAMAGED IF RUN IN SEQUENCE
WITHOUT A CASE DRAIN HOOK UP BACK TO THE RESERVOIR.
FLOW
CONTROL VALVE
MUST be located on
inlet side of motor
ADDITIONAL DETAILS AVAILABLE ONLINE AT www.vibco.com
1. Be sure steps 1-11 are complete before starting vibrator. Missing
a step can cause vibrator failure & void warranty.
2. Always check pressure to & from vibrator with a pressure gauge.
If inlet pressure exceeds 1200psi (82 bar) or outlet pressure
exceeds 30psi (2 bar) check for restrictive fittings or increase
hose size. Be sure case drain is hooked up as a return to
reservoir. For Model’s B outlet should be directly connected to
the oil reservoir and carry NO back pressure.
3. Do a quick inspection of hydraulic oil. If dark or thick, replace
with new oil.
4. Inspect structure for cracks or fatigue and repair if any are found.
5. Run unit for 5-10 seconds & check all fittings for leaks.
WARNING!
HYDRAULIC OIL UNDER PRESSURE CAN PENETRATE SKIN
AND RESULT IN INJECTION POISONING. IF OIL PENETRATES SKIN CONSULT
WITH A DOCTOR IMMEDIATELY!
CHECK LINE PRESSURE
Always check pressure to & from
vibrator with a pressure gauge.
Insert gauge in-line with the vibrator
before & after the inlet/outlet.
If inlet pressure exceeds 1200psi
(82 bar) or outlet pressure exceeds
30psi (2 bar) check for restrictive
fittings or increase hose size.
INLET
PRESSURE
OUTLET
PRESSURE
13
MAINTENANCE
Check tightness of
mounting bolts every
200 hours or every
month of operation.
Check tightness of
all hydraulic hoses
and connections.
Inspect hydraulic oil
on a periodic basis. If
dark or thick replace
with new oil.
Check structure for cracking
or fatiguing. If found, repair
before running unit. Call
VIBCO for instructions to
repair fatigue cracking.
14
TROUBLESHOOTING
LEAKING OIL?
1. Check tightness of all hydraulic fittings.
2. Be sure the check valve is installed in the proper direction with the flow of
hydraulic oil.
3. Check outlet line pressure (panel 12). If outlet line pressure is over 30psi
case drain hose to reservoir MUST be installed.
4. End cover leaks on B-Series vibrator is a result of high oil pressure.
Check castings for cracks & contact VIBCO immediately.
5. If shaft seals are leaking on H-Series vibrator contact VIBCO for
replacement kit & instructions. Shaft seal failure is due to excessive back
pressure & case drain MUST be installed.
Use this handy
QR Code
to get any of our
Product Catalogs