ONX-220 User's Guide
22135173, Rev. 000
June 2020
84
Chapter
4 CATV Testing
ChannelCheck
The Channel Check test provides real-time analysis of Downstream QAM and Analog
Carriers.
The ChannelCheck test conducts the same test done by OneCheck Upstream checking for
interference into the signal. It analyzes OFDM carriers including multiple DS profiles.
Channel check can also be used to quickly check levels and signal performance.
To run a ChannelCheck
1. Select
ChannelCheck
under the CATV menu header. The ChannelCheck Setup
screen appears.
2. Select the desired demarcation point to be tested: Tap, Ground Block or CPE. A
graphic showing the appropriate connection schematic for this test will appear
along with appropriate instructions for the port to be used.
3. Assign this test to a saved work order (optional but recommended).
Select the
Work Order ID
button and the list of available work orders will
appear. Select one.
4. Start the test by selecting the
Start
button at the bottom of the screen.
Results
For a detailed discussion of the results produced by this test, see
Saving results
To capture a snapshot of the results for review, press the
Stop
button.
To save for later review, press the
Save
button and then give them a name.
Summary of Contents for ONX-220
Page 1: ...ONX 220 User s Guide ...
Page 8: ...ONX 220 User s Guide 22135173 Rev 000 June 2020 8 ...
Page 34: ...ONX 220 User s Guide 22135173 Rev 000 June 2020 34 Chapter 1 Quick Tour ...
Page 78: ...ONX 220 User s Guide 22135173 Rev 000 June 2020 78 Chapter 3 Menus and Workflow ...
Page 98: ...ONX 220 User s Guide 22135173 Rev 000 June 2020 98 Chapter 5 Ethernet Testing ...
Page 198: ...ONX 220 User s Guide 22135173 Rev 000 June 2020 198 Chapter 11 Test Results ...
Page 211: ......