700
JD700B Series User’s Guide
Figure 415 Example of running favorite with progress on top of the window
Performing RRH profiling
If the RRH is new and no file has been saved that can be used for the RRH configuration, you need to run
the RRH Profiling and capture the C&M messages first, and then retrieve profile parameter values the RRH
Profiling to capture C&M messages, and retrieve profile parameter values, such as RHH vendor, technology,
VSWR level, RSSI level, carrier frequency, Link ID, and RE ID, from both BBU and RRH. If you already have
a saved profile that works for the RRH, you can skip this RRH Profiling.
Connecting cables
To perform the RRH profiling, make the Thru mode cable connection as illustrated in Figure 416.
Figure 416 Thru connection diagram
With nTap (both Thru On/Off):
Without nTap (Thru On only):
Enabling Thru mode in CellAdvisor
Procedure
1
Press the
BBU Emulation > Alcatel-Lucent
soft key.
2
Select
Profiling
.
3
Press the
MEASURE SETUP
hot key.