Specifications, ATC-5000NG Performance Specifications
Environmental
, Full Specified Performance
1-3-1
ATC-5000NG ATC/DME Test Set Operation Manual
Rev. L0
Page 12
Subject to Export Control. See Cover Page for details.
February 2020
DME Position:
Squitter/Echo/Ident/Reply:
4.5
s prior to first pulse of any selected
transmission
Accuracy:
0.5
s
Interrogation:
2.5
s following the rising edge of received
interrogation pulse P1
Accuracy:
0.5
s typical
1.3
ENVIRONMENTAL
1.3.1
FULL SPECIFIED PERFORMANCE
23°C (
5°C)
Full specification performance requires a 1
hour warm-up from cold start.
1.3.2
OPERATING
0°C to 40°C
1.3.3
STORAGE
0°C to +71°C
1.3.4
RELATIVE HUMIDITY
0 to 95% non-condensing
1.3.5
DEGREE OF PROTECTION
IPX-0
1.3.6
PHYSICAL
Overall Dimensions:
10.5 in (H) x 19 in (W) x 24 in (D)
(26.7 cm x 48.3 cm x 60.9 cm)
Weight:
41 lbs. (19 kg)
1.4
AC INPUT POWER
1.4.1
VOLTAGE RANGE
100 to 240 VAC, 50 to 60 Hz
1.4.2
POWER CONSUMPTION
100 W typical
Summary of Contents for 138156