4.2.3.2 Verifying the Signal on the Agri-Alert 9600
(Advanced function)
On the AA9600 :
1. Press the
System
key.
2. Enter the installer’s password (9601 by default) and press
Enter
.
3. Select the
PROGRAM AUX’S
menu and press
Enter
.
4. Select the
INFORMATION
menu and press
Enter
.
5. Enter the number associated with the device you want to access from a remote
location and press
Enter.
6. Communication statistics on the selected device are displayed: the
Loss
value
repesents the number of packet loss and the
Total
represents the number of sent
packets (the total value automatically goes back to 0 once it reaches 65000 or after
a reset)
7. Press the right-arrow key to reset the communication statistics.
8. Wait until the total number of packets reaches 500 and check the number of packet
loss at that moment. In an excellent installation, the amount of packet loss would be of
15 out of 500 or less (3% loss). This loss rate is only reached in perfect conditions, an
application can be functional with a higer packet loss rate.
If you want to improve your communication statistics, try relocating the antennas
and make sure the cables are in good working conditions.