98MANALX17 Rev. A 6/23/10
Page 4
Standard Wiring:
Model 517/WW517
Model LP717/817
Wiring
:
Wiring:
Red: +Signal
Red: + Power
Black: -Signal
Black: + Signal
Green: Case Ground
Green: - Power
White: - Signal
Mechanical Installation:
Models 517, LP717 and 817 are generally suspended directly into the media. An optional nose cone can be ordered to
replace the standard cap for hanging weights on the unit to prevent movement. It is recommended that the weight be limited to a
maximum of two pounds. Another method is to anchor the unit to a rigid fixture using the optional male conduit connection or by
means of a bracket.
The Model WW517 is also generally suspended in the media however it comes equipped with an additional stainless
steel wire capable of holding up to two hundred pounds. It is suggested that this wire be used for placing and retrieving the unit
rather than the electrical cable. The end should be tied off at the termination end so prevent it from falling into the tank.
Standard Wire Information:
Specifications:
Standard Polyurethane Cable
Weight
0.04 lbs/ft.
OD
0.25"
Max Pulling Tension
30 lbs.
Conductors
4-24 AWG
Insulation:Conductors/Jacket
PVC/Polyurethane
Drain/Shield
32AWG
Vent Tube
0.085 OD Nylon
conductor Resistance
0.026 ohms/ft