background image

INSTALLATION DATA

 

Model 509

 

Wiring:

 

Model 709

 

Wiring:

 

Model 809

 

Wiring:

 

Pin A:

 

Pin B: 

Pin C: 

Pin D: 

Pin E:

 

+Signal

 

- Signal

 

No Connection

 

No Connection

 

+Calibration

 

Pin A:

 

Pin B: 

Pin C: 

Pin D: 

Pin E: 

Pin F:

 

+Power

 

- Power

 

+Signal

 

- Signal 

  Calibration  

  Calibration

 

Pin A:

 

Pin B: 

Pin C: 

Pin D: 

Pin E: 

Pin F:

 

+Power

 

-Power

 

+Signal  

-Signal 

  Calibration 

  Calibration

 

ADAPTER 

ASSEMBLY 

Pin F:   - Calibration

 

Grn Ter: Case Ground

 

SENSOR 

ASSEMBLY 

O-RING 

Grn Ter: Case Ground

 

Grn Ter: Case Ground

 

To activate cal on Model 509, the cal circuit must be powered.

 

To activate cal on Models 709 & 809 short pins E & F.

 

Input:

 

9-30VDC

 

10.5-28 VDC

 

Input:

 

9-30VDC

 

10.5-28 VDC

 

Input:

 

10-15VDC

 

input for approved units

 

Fig.2 

Adapter & Connector Bolt Torque Settings*

 

Connector Fasteners:

 

Size 4-40 (with gasket) = 4 in-lbs 

Size 4-40 (no gasket) = 8 in-lbs 

Size 6-32 = 25 in-lbs 

Adapter Fasteners:

 

Size 8-32 = 40 in-lbs 

Output:

 

4 to 20mA

 

Output:

 

0 to 5VDC

 

Output:

 

3.0mV/V

 

Sensor Construction:

 

All Ranges: Inconel X-750

 

Electrical Connector:

 

6 pin bayonet (standard)

 

Lightly hand-tighten bolts in alternating fashion (star pattern).  Ensure that the item to be secured is fully and evenly

 

seated, and the O-ring, if applicable, is fully compressed.  Torque bolts in alternating fashion (star pattern).

 

Pressure Connection By Range:

 

5,000, 10,000, 15,000 & 20,000 PSI: 1502 Hammer Union

 

Connection Diagrams

 

(Non Hazardous environments)

 

For Hazardous locations, see attached connection

 

Diagram per approval code ordered.

 

STANDARD VIATRAN PRODUCT MARKING

 

MODEL  509 

MODEL  709  & 809 

98MANALX09   Rev, K 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

     

     

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

   

   

 

 

 

 

 

 

 

 

   

 

 

  

 

 

 

 

 

   

 

 

 

VOLT 

 

 

Summary of Contents for 509

Page 1: ...DATA MANUAL MODEL 509 709 809 PRESSURE TRANSMITTER 199 Fire Tower Drive Tonawanda NY 14150 Int l 1 716 629 3800 Toll Free 1 800 688 0030 Fax 1 716 693 9162 www viatran com solutions viatran com 1 98MANALX09 Rev K 0 ...

Page 2: ...ucts installed in areas where the potential for contamination at the electrical connection is possible protective measures be taken to eliminate possible deterioration of the product s electrical connection and corrosion that will impede product performance At no time should an object be inserted into the pressure port or pressed against the sensing area to deflect the sensor to test or simulate p...

Page 3: ...d units Fig 2 Adapter Connector Bolt Torque Settings Connector Fasteners Size 4 40 with gasket 4 in lbs Size 4 40 no gasket 8 in lbs Size 6 32 25 in lbs Adapter Fasteners Size 8 32 40 in lbs Output 4 to 20mA Output 0 to 5VDC Output 3 0mV V Sensor Construction All Ranges Inconel X 750 Electrical Connector 6 pin bayonet standard Lightly hand tighten bolts in alternating fashion star pattern Ensure t...

Page 4: ...aken in the handling and application of the product Older products returned for repair are updated to current specifications unless the repair cost would outweigh the cost of a new replacement model Products returned for repair should include information on the person to contact for repair quote approval the individual to contact if Viatran s technical staff requires additional information during ...