AirBP 2 

Blood Pressure Monitor 

 
 

 

 
 

 
 

 
 
 

 

User Manual (EN) 
Benutzerhandbuch (DE) 
Manuale d'uso (IT) 
Manual de usuario (ES) 
Manuel de l'utilisateur (FR) 

Summary of Contents for Wellue AirBP 2

Page 1: ...AirBP 2 Blood Pressure Monitor User Manual EN Benutzerhandbuch DE Manuale d uso IT Manual de usuario ES Manuel de l utilisateur FR ...

Page 2: ...Contents User Manual English 1 16 Benutzerhandbuch Deutsch 17 35 Manuale d uso Italiano 36 54 Manual de usuario Español 54 71 Manuel de l utilisateur Français 72 89 ...

Page 3: ... Battery 6 3 2 Beep indications 7 3 3 Applying the Arm Cuff 7 3 4 How to Sit Correctly 8 3 5 Connect to the App 8 3 6 Measurement 9 3 7 After the Test 9 3 8 Reviewing the History 10 3 9 Measurement without App 11 3 10 Trouble Shooting 11 4 Accessories 12 5 Specifications 12 6 Maintenance 14 6 1 Maintenance 14 6 2 Cleaning 14 6 3 Storage 15 7 Electromagnetic Compatibility 15 ...

Page 4: ...oft cloth or a cloth dampened with water and a neutral detergent Never use alcohol benzene thinner or other harsh chemicals to clean the device or cuff Avoid tightly folding the cuff or storing the hose tightly twisted for long periods as such treatment may shorten the life of the components Do not use in a location with moisture or a location where water may splash on the device This may damage t...

Page 5: ... disorders as cuff inflation can cause bruising People who have a severe circulatory deficit in the arm must consult a physician before using the device to avoid medical problems Do not self diagnose the measurement results and start treatment by yourself Always consult your physician for evaluation of the results and treatment Do not apply the cuff on the injured arm or the arm under medical trea...

Page 6: ...onatal pregnant including pre eclamptic patients When choosing a third party charging adaptor select one that complies with IEC 60950 or IEC 60601 1 Dispose of the device components and optional accessories according to applicable local regulations Unlawful disposal may cause environmental pollution 2 Introduction 2 1 Device Description The blood pressure monitor includes two models BP1 and BP1A I...

Page 7: ...cilities by using a non invasive oscillometric technique with a single upper arm cuff 22 42 cm 2 3 Contraindications The use of this device is prohibited in ambulatory environments The use of this device is prohibited on aircraft 2 4 Symbols Symbol Description Manufacturer Date of manufacture SN Serial number Indicates a medical device that is not to be disposed of as unsorted municipal waste Foll...

Page 8: ...g Authorized Representative in the United Kingdom This product complies with the rules and regulations of the Federal Communication Commission 3 Using the Monitor Download the App AirBP iOS App Store Android Google Play Note if you ve downloaded the App before please update to the latest version 3 1 Charging the Battery Charge the monitor by using the USB cable to connect a USB charger or to the P...

Page 9: ...d of measurement Three short beeps Pump pressure is too high above 300mmHg 3 3 Applying the Arm Cuff Wrap the cuff around the upper arm about 1 to 2cm above the inside of the elbow as shown Place the cuff directly against the skin as clothing may cause a faint pulse and result in a measurement error Constriction of the upper arm caused by Do not roll up shirtsleeve too tightly Artery position mark...

Page 10: ... legs uncrossed and your feet flat on the floor Sit with both your back and arm being supported Place your arm on a table so the cuff is level with your heart 3 5 Connect to the App 1 Turn on the Phone s Bluetooth 2 Press the button to power on the monitor 3 Open the Air BP APP on your smartphone The App will search for the device Choose your device AirBP xxxx in the App Note Keep the monitor and ...

Page 11: ... according to instructions of the App hold the pump without squeezing it and wait for the further instructions In some cases if the App senses that the pressure in the cuff is not high enough for use then the user will be instructed to pump again Note During use you should keep your body still Otherwise the blood pressure readings may be inaccurate Stop pumping when the screen of the monitor show ...

Page 12: ...automatic deflation On the results page you can add user names and ID s to help you manage multiple users data add notes share results or delete them If the monitor detects an irregular heartbeat then the corresponding symbol will display below the PR value Note The device will turn off automatically after two minutes if not working 3 8 Reviewing the History ...

Page 13: ...wait for the further instructions In some cases if the monitor senses that the pressure in the cuff is not high enough for use then the user will be instructed to Pump again 4 After the test The blood pressure readings will appear on the screen of the monitor when the test has finished You need to manually press the exhaust valve to deflate the cuff Note If you want to start a new measurement you ...

Page 14: ...tatus Reset the device by pressing and holding the button for 5s Cannot get blood pressure readings The measurement is interrupted by arm movement or unexpected bulb squeezing during use Keep the arm still and don t squeeze the bulb during deflation There is pressure leakage Check the hose connection to see if it is loose 4 Accessories Model Description CU 10 Adult arm size 22 42cm 540 00240 00 MI...

Page 15: ...68mm long 25mm diameter main unit Weight Less than 30 g main unit Cuff size Adult cuff 22 42cm Wireless connectivity Built in Bluetooth 4 0 BLE Power Supply Charger input Micro USB DC5V Battery type Rechargeable lithium polymer battery Estimated charging time Approximately 2 hours Blood Pressure Technology Oscillometric method Cuff pressure Range 0 300 mmHg Pressure measurement accuracy 3mmHg Puls...

Page 16: ...store the monitor and the components in a clean safe location Caution DO NOT disassemble or attempt to repair this monitor or other components This may cause inaccurate blood pressure readings 6 2 Cleaning Do not use any abrasive or volatile cleaners Use a soft dry cloth or a soft cloth moistened with mild neutral detergent to clean your monitor and the arm cuff and then wipe them with a dry cloth...

Page 17: ...nents in locations exposed to extreme temperatures humidity direct sunlight dust or corrosive vapors such as bleach Disposal 7 Electromagnetic Compatibility The device meets the requirements of EN 60601 1 2 Using accessories other than those specified in this manual may result in increased electromagnetic emissions or decreased electromagnetic immunity for the device The device or its components s...

Page 18: ...n the inputted signal is below the minimum amplitude provided in the technical specifications erroneous measurements could result Portable and mobile communication equipment may affect device performance Other devices that have RF transmitters or sources may affect this device e g cell phones PDAs and PCs with wireless functionality The EMC table information is listed on our website http api viato...