ArcLight Hub User’s Guide
Component Operating Procedures
5-62 1081006
Rev.
001
A summary of actions necessary to set up the VPCMA-70 are listed in
Table 5-17.
Table 5-17. VPCMA-70 Set Up Quick Guide and Summary.
Action
Summary
Parameters Required
Before Configuring the
PCMAHC
Determine parameters to be entered using the parameters listed in the
PCMAHC installation section of the ArcLight Hub Installation and
Maintenance Guide.
Turning On and
Configuring the PCMAHC
Power on the equipment. Use the front panel to configure the PCMAHC
using the parameters from the PCMAHC installation section of the
ArcLight Hub Installation and Maintenance Guide.
Remote Control
Optionally configure the unit for remote control.
Normal Operation
Check all connections and assume normal operations.
Redundancy Operation
Repeat steps above for the redundant unit(s). Each unit should have
identical parameters.
The PCMA SYSTEM and CANCELLER function parameters must be set
for each site location by performing the steps in Table 5-18. Use the
cursor keys to navigate to each of the display menus.
Table 5-18. Initial VPCMA-70 Configuration Setup
Step Display
or
Function
Procedure/Description
Front Panel Display
1.
Turn Power On
Turn power on using the
I - O
switch on
the rear panel near the power cord
connection.
Note:
If the Canceller function is
activated, the SYSTEM Menu will be
replaced with the Canceller Enable
message in the display.
POWER LED lights. After
about 30 seconds, the front
panel display should show
the SYSTEM Menu, and all
front panel LEDs should
momentarily go on and then
go off. LEDs remaining on
indicate the function is
active.
Set System
Parameters
Access and set the system parameter
functions. Initial system parameters
must be set using the front panel
display.
------------------
Go to SYSTEM
Menu
Press right or left arrow key until
SYSTEM Menu is displayed.
SYSTEM Menu displayed
Select Local
Control
Press down arrow key to view
Local/Remote Menu. If Local is NOT
selected, press ENTER. Use up/down
keys to show options. When Local is
displayed, press ENTER.
Local displayed in menu.
REMOTE LED – off.
2.
Enter IP Address*
Press right arrow key to view Menu. To
change, press ENTER and use number
keys to enter IP address of VPCMA-70.
Press ENTER when done. Be sure to
enter leading 0s if needed.
IP Address
nnn.nnn.nnn.nnn
The range for each ‘nnn’ set
is ‘000’ to ‘255’
Summary of Contents for ArcLight
Page 2: ......
Page 3: ...ArcLight TM Hub User s Guide ViaSatDocument Number 1081006 Rev 001 ...
Page 4: ......
Page 5: ...ArcLightTM Hub User s Guide ...
Page 6: ......
Page 7: ...ArcLight TM Hub User s Guide ViaSatDocument Number 1081006 Rev 001 ...
Page 9: ......
Page 10: ......
Page 12: ...ArcLight Hub User s Guide iv 1081006 Rev 001 ...
Page 35: ...ArcLight Hub User s Guide Rev 001 1081006 xxvii ...
Page 36: ......
Page 64: ...ArcLight Hub User s Guide General System Description 1 28 1081006 Rev 001 ...
Page 70: ...ArcLight Hub User s Guide Initial Network Configuration 2 6 1081006 Rev 001 ...
Page 237: ...ArcLight Hub User s Guide Screen Descriptions for NMS Client Rev 001 1081006 3 167 ...
Page 238: ......
Page 364: ...ArcLight Hub User s Guide A 2 1081006 Rev 001 ...
Page 366: ...ArcLight Hub User s Guide B 2 1081006 Rev 001 ...
Page 368: ...ArcLight Hub User s Guide I 2 1081006 Rev 001 ...