IMPORTANT SAFETY INSTRUCTIONS

CAUTION - To reduce risk of electrical shock or electrocution:

- Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service  

  agencies for all service and repairs.

- Do not use this product in an area where it can fall or be pulled into water or other liquid.

- Do not reach for this product if it has fallen into liquid. 

- Use this compressor with 12-Volt DC systems only.

- This product should never be left unattended during use.

WARNING - To prevent injury:

-  Never allow children to operate this compressor. Close supervision is necessary when this 

  compressor is being used near children.

-  This compressor will become very HOT during and immediately after use. Do not touch any part of this 

  compressor with bare hands, other than the ON/OFF switch, during and immediately after use. 

-  Do not use this product near flames or explosive materials or where aerosol products are being used.

-  Do not operate this product where oxygen is being administered. 

- Do not pump anything other than atmospheric air.

-  Never use this product while sleepy or drowsy.

-  Do not use any tools or attachments without first determining maximum air pressure for that 

  tool or attachment.

-  Never point any air nozzle or air sprayer toward another person or any part of the body.

- Wear safety glasses or goggles when operating this product.

-  Use only in well ventilated areas.

INSTALLATION

Please read and follow the installation instructions carefully to avoid injury or damage to the 

compressor and your vehicle. Each of our air compressors and parts have been carefully produced 

and packaged. Before you begin installation, please familiarize yourself with Installation Parts List 

(Fig. 1) of this manual. 

Selecting a Mounting Location: 

The selection of proper mounting location for your air compressor will help ensure a long and 

trouble free compressor service life. Please pay close attention to the following guidelines: 

1. Select a FLAT, UPRIGHT AND SECURE location where the compressor can be mounted.
2. To maximize air compressor performance, locate compressor as CLOSE TO THE BATTERY  

as possible so that length of positive lead wire required is at a minimum. 

3. Choose mounting location that is as cool as possible and AWAY FROM HEAT SOURCES.  

The cooler the ambient temperature the less chance the compressor will overheat. 

4. This compressor is moisture & splash resistant, but NOT WATER OR DUST PROOF. Do not mount 

compressor in locations where the unit is likely to come in contact with water.

5. If it is necessary to mount the air compressor further away from the battery, such as inside  

your vehicle or in the bed of your pickup, use a minimum 16 AWG positive lead wire for remote 

installation. (See wire gauge reference chart)

6. Do not mount compressor near areas where flammable liquids are stored.

Summary of Contents for 65C

Page 1: ...It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE 65C COMPRESSOR KIT 12V P N 00065 ...

Page 2: ...y Wear safety glasses or goggles when operating this product Use only in well ventilated areas INSTALLATION Please read and follow the installation instructions carefully to avoid injury or damage to the compressor and your vehicle Each of our air compressors and parts have been carefully produced and packaged Before you begin installation please familiarize yourself with Installation Parts List F...

Page 3: ...your compressor setup is properly fused For appropriate fuse size refer to Amp draw of compressor in the specifications section of this manual 7 Always locate fuse as close as possible to power source 8 Before connecting to power source re check to make sure a that all connections are properly connected 9 Connect and test compressor system by running the compressor for a short time to build up pre...

Page 4: ...k all mounting screws Tighten as needed 3 Regularly clean dust and dirt from compressor cooling fins and motor housing 4 Your air compressor is equipped with permanently lubricated maintenance free motor Never try to lubricate compressor 5 All repairs should be performed by Manufacturer or Manufacturer s Authorized Service Agencies only CAUTION Never touch the air compressor or fittings connected ...

Page 5: ...se connections 1 Tighten drain cock 2 Replace check valve or compressor 3 Check all connections with soap and water solution and tighten Compressor runs continuously and air flow lower than normal 1 Excessive air usage 2 Loose connections 3 Worn piston ring or inlet valve 4 Clogged air filter element 1 Decrease air usage 2 Check all connections with soap and water solution and tighten 3 Replace co...

Page 6: ...0 100 200 PSI ABOUT COMPRESSOR DUTY CYCLE Duty cycle refers to the amount of time a compressor can be operated in a given time period at 100 PSI and a standard ambient temperature of 72 F It is commonly expressed in percentage format Compressor on time on time off time Duty Cycle ONE HOUR DUTY CYCLE MINUTES ON 100 PSI 72 F MINUTES OFF 9 5 min On 55 min Off 10 6 min On 54 min Off 15 9 min On 51 min...

Page 7: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 8: ... is proprietary to VIAIR Corporation and no ownership rights are hereby transferred No part of the Manual shall be used reproduced translated converted adapted stored in a retrieval system communicated or transmitted by any means for any commercial purpose including without limitation sale resale license rental or lease without the prior express written consent of VIAIR VIAIR does not make any rep...